CHICAGO, IL —
OSHA Inspection: FRAME & FINISH CARPENTERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FRAME & FINISH CARPENTERS, INC. in 231 WEST SCOTT STREET, CHICAGO, IL 60610 (NAICS 238130). OSHA activity number 343108155.
Where did this inspection happen?
- Establishment
- FRAME & FINISH CARPENTERS, INC.
- Site address
- 231 WEST SCOTT STREET
- City
- CHICAGO
- State
- IL
- ZIP
- 60610
- Mailing
- 1249 PARK AVE., CHICAGO HEIGHTS, IL 60412
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
8 citations on file for this inspection.
1903.19 C01
- Issued
- Abate by
- Penalty
- Initial $311.00 · Current $311.00
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: Frame & Finish Carpenters, Inc. failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 01 01 05/25/2018 01 03a 05/25/2018 01 03b 05/25/2018 01 03c 05/25/2018 01 04a 05/25/2018 01 04b 05/25/2018 In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (O) $311
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2217.00 · Current $2217.00
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) On or about April 24, 2018, employees were exposed to eye injury while operating nail guns without the benefit of eye protection. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $2217
1926.501 B13
- Issued
- Penalty
- Initial $3880.00 · Current $3880.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On or about May 24, 2018, employees were exposed to the hazard of falling approximately 17 feet to the exterior of the building while performing carpentry work from the top of exterior walls. b) On or about May 24, 2018, employees were exposed to the hazard of falling approximately 27 feet to the exterior of the building while performing carpentry work from the edges of upper level floors. No abatement certification or documentation required for this violation.
Recent events (1)
- — Z (S) $3880
1926.1052 C01 I
- Issued
- Abate by
- Penalty
- Initial $3326.00 · Current $3326.00
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) On or about April 24, 2018, stairways between the first level of the building and the upper work levels where carpentry work was being conducted were not equipped with at least on handrail. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $3326
1926.1052 C01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) On or about April 24, 2018, stairways between the first level of the building and upper work levels where carpentry work was being conducted were not equipped with stairrail systems along unprotected sides or edges. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $0
1926.1052 C12
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926; a) On or about April 24, 2018, a stairway landing between the main level of the building and an upper level was as not equipped with a guardrail system along its unprotected sides or edges. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $0
1926.1053 A01 II
- Issued
- Abate by
- Penalty
- Initial $3326.00 · Current $3326.00
General-duty citation text
29 CFR 1926.1053(a)(1)(ii): Job-made ladder were not built in conformance with applicable provisions of Appendix A: a) On or about April 24, 2018, the cleats/rungs of a job-made ladder provided for employee use to enter and exit the building were not joined/spliced to the ladder rails as prescribed by American National Standards Institute (ANSI) A14.4-1992 - Safety Requirements for Job-Made Ladders. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $3326
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about April 24, 2018, a portable job-made ladder used to enter and exit the building did not extend above the landing surface at an elevation of about 7 feet. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $0
More inspections at FRAME & FINISH CARPENTERS, INC.
CHICAGO, IL—2019-08-15 00:00:00
FRAME & FINISH CARPENTERS, INC.
View FRAME & FINISH CARPENTERS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
MOUNT JULIET, TN—2026-07-17 00:00:00
M AND F CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
CARRILLO CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
SEVY BROTHERS CONSTRUCTION LLC
WESTFORD, MA—2026-07-17 00:00:00
M&M CONSTRUCTION SERVICES CORP
FAIRHOPE, AL—2026-07-16 00:00:00
FRANCISCO ARIAS
More inspections in IL
FRANKFORT, IL—2026-07-17 00:00:00
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17 00:00:00
AUGUSTANA COLLEGE
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
FOREST PARK, IL—2026-07-17 00:00:00
CONSERVATION OF SCULPTURE & OBJECTS STUDIO, INC.
BLUE ISLAND, IL—2026-07-17 00:00:00
PROFLOW PUMPING SOLUTIONS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343108155.