TEANECK, NJ —
OSHA Inspection: MH RESTORATION INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MH RESTORATION INC in 362 CEDAR LN, TEANECK, NJ 07666 (NAICS 238160). OSHA activity number 343115432.
Where did this inspection happen?
- Establishment
- MH RESTORATION INC
- Site address
- 362 CEDAR LN
- City
- TEANECK
- State
- NJ
- ZIP
- 07666
- Mailing
- 8 AVENUE J, LAKE RONKONKOMA, NY 11779
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Penalty
- Initial $3880.00 · Current $2328.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a) Roof - Cedar Ln Façade: Employees were installing roofing material next to the 18" parapet without any means of fall protection or monitoring system in place, employees were exposed to fall hazards of approximately 26 feet, on or about 4/26/18
Recent events (2)
- — I (S) $2328
- — Z (S) $3880
1926.1053 B01
- Issued
- Penalty
- Initial $2772.00 · Current $1663.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Roof - Cedar Ln Façade: Employees were utilizing a fiberglass extension ladder that did not reach the top of the parapet wall to access the roof 26 feet above the concrete sidewalk, on or about 4/26/18
Recent events (2)
- — I (S) $1663.2
- — Z (S) $2772
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16 00:00:00
MARVIN PINERA
CARSON CITY, NV—2026-07-16 00:00:00
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16 00:00:00
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16 00:00:00
CARLOS CHE
BALTIMORE, MD—2026-07-16 00:00:00
VAL CONSTRUCTION INC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16 00:00:00
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16 00:00:00
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15 00:00:00
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15 00:00:00
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343115432.