Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ROBINSON MAINTENANCE & REPAIRS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROBINSON MAINTENANCE & REPAIRS INC. in 1022 KENILWORTH AVE., OAK PARK, IL 60302 (NAICS 238220). OSHA activity number 343120762.

Watch Robinson Maintenance & Repairs INC. — free Get an email when a new federal OSHA severe-injury report for Robinson Maintenance & Repairs INC. is published. One employer, no account, unsubscribe in one click.
Site address
1022 KENILWORTH AVE.
City
OAK PARK
State
IL
ZIP
60302
Mailing
919 NATIONAL AVE., ADDISON, IL 60101
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $1552.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):       a) On April 26, 2018, employees engaged in chimney lining work were not protected from fall hazards while working at an elevation of approximately 21.5 feet above the ground.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1552
  • — Z (S) $3880

1926.503 A01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $1000.00 Reduced
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee who might be exposed to fall hazards:      a)  On or about April 26, 2018, employer did not provide training to each employee in order to recognize hazards associated with working at an elevation and to understand procedures to control or minimize those hazards.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $1000
  • — Z (S) $2772

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2772.00 · Current $948.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:      a)  On April 26, 2018, an extension ladder used by employees to gain access to the roof did not have it's side rails extend at least 3 feet above the roof eave.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $948
  • — Z (S) $2772

1926.1053 B16

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:    a)  On April 26, 2018, a portable ladder used by employees onsite had structural defects, such as, damaged siderails.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View ROBINSON MAINTENANCE & REPAIRS INC.'s full OSHA safety record →