OSHA Inspection: MEJIA BROTHERS CONSTRUCTION INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of MEJIA BROTHERS CONSTRUCTION INC. in 5 ATLANTIC AVE., EAST ROCKAWAY, NY 11518 (NAICS 238130). OSHA activity number 343170700.

Watch Mejia Brothers Construction INC. — free Get an email when a new federal OSHA severe-injury report for Mejia Brothers Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
5 ATLANTIC AVE.
City
EAST ROCKAWAY
State
NY
ZIP
11518
Mailing
565 FULTON AVE., HEMPSTEAD, NY 11550
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1550.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    a) Worksite: Employees performing framing work a pneumatic nail gun were not provided with safety glasses. Employees were exposed to struck by hazards from flying particles; on or about 5/18/18.      Abatement certification is required for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1550
  • — Z (S) $2217

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $1940.00 Reduced
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated:    a) Worksite: An employee was doing framing work from a JLG 450AJ aerial lift. The employee was not wearing a body belt and/or a lanyard was not attached to the basket and was exposed to falls of up to and including approximately 20 ft. to the ground below; on or about 5/18/18.    Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1940
  • — Z (S) $2772

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2718.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) Worksite: Employees who were framing the residential construction without fall protection were exposed to falls of up to and including approximately 20 ft. to the ground below; on or about 5/18/18.    Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2718
  • — Z (S) $3880

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343170700.