Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BLIZZARD COOLING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BLIZZARD COOLING INC. in 550 KINGSTON AVENUE, BROOKLYN, NY 11203 (NAICS 238220). OSHA activity number 343183091.

Watch Blizzard Cooling INC. — free Get an email when a new federal OSHA severe-injury report for Blizzard Cooling INC. is published. One employer, no account, unsubscribe in one click.
Site address
550 KINGSTON AVENUE
City
BROOKLYN
State
NY
ZIP
11203
Mailing
5308 13TH AVENUE SUITE #113, BROOKLYN, NY 11219
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.95 A

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2956.00 · Current $1875.00 Reduced
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact.      Location:  a) On the second floor of the jobsite:      On or about 05/24/18, employees were installing piping and ducts without personal protective equipment for head and foot, and were exposed to struck by or puncture hazards.
Recent events (3)
  • — F (S) $1875
  • — C (S) $2956
  • — Z (S) $2956

1926.96

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.96: The employer did not ensure employees wear proper footwear which meets the requirements and specifications in American National Standard for Men's Safety-Toe Footwear, Z41.1-1967.        Location:  a) On the second floor of the jobsite:      On or about 05/24/18, employees were installing piping and ducts without personal protective equipment for head and foot, and were exposed to struck by or puncture hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.100 A

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    Location:  a) On the second floor of the jobsite:      On or about 05/24/18, employees were installing piping and ducts without personal protective equipment for head and foot, and were exposed to struck by or puncture hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.300 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2956.00 · Current $1875.00 Reduced
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use.       Location:   a) On the second floor of the jobsite:                                                        On or about 05/24/18, employees used a portable hand grinder without a guard to cut piping and ducts.
Recent events (3)
  • — F (S) $1875
  • — C (S) $2956
  • — Z (S) $2956

View BLIZZARD COOLING INC.'s full OSHA safety record →