CAROL STREAM, IL —
OSHA Inspection: GRUNT STYLE LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GRUNT STYLE LLC in 400 E. FULLERTON AVE. N1, CAROL STREAM, IL 60188 (NAICS 323113). OSHA activity number 343259214.
Where did this inspection happen?
- Establishment
- GRUNT STYLE LLC
- Site address
- 400 E. FULLERTON AVE. N1
- City
- CAROL STREAM
- State
- IL
- ZIP
- 60188
- Mailing
- 680 CENTER AVE., CAROL STREAM, IL 60188
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323113
- Employees
- 300
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $6097.00 · Current $3049.00 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: (a) prepare for shut down by recognizing energy hazards and its controls, (b) turn off and shut down the machines, (c) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (d) affix lockout or tagout devices to each energy isolating device, (e) render safe all potentially hazardous stored or residual energy, (f) verify that isolation and de-energization of the machine or equipment have been accomplished. Production, screen printing machines: on or about June 27, 2018, employees assigned to add ink (service and maintenance) to color trays were exposed to caught-in and struck-by hazards while hazardous energy controls (lockout) were not done in the sequence as required by 29 CFR 1910.147(d)(1)-(6). Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $3048.5
- — Z (S) $6097
1910.132 E
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(e): Defective and damaged equipment. Defective or damaged personal protective equipment shall not be used. Production, spray blast/cleaning work station: on or about June 27, 2018, employees spot spraying ink soiled apparel with a cleaning fluid were provided with a single pair of damaged (cut) gloves for shared use. Employees' fingers and hands were exposed to contact with the cleaning fluid likely to result in skin irritation. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GRUNT STYLE LLC
CAROL STREAM, IL—2019-05-24 00:00:00
GRUNT STYLE LLC
CAROL STREAM, IL—2018-07-03 00:00:00
GRUNT STYLE LLC
CAROL STREAM, IL—2017-09-07 00:00:00
GRUNT STYLE LLC
CAROL STREAM, IL—2017-08-30 00:00:00
GRUNT STYLE LLC
View GRUNT STYLE LLC's full OSHA safety record →
More inspections in this industry (NAICS 323113)
CHICAGO, IL—2026-07-08
SOARDIST USA INC. DBA SOARDIST DISPLAYS AND APPAREL
PENNOCK, MN—2026-07-06
111536 - MINNESOTA SCREEN PRINT - EMBROIDERY INC
PENNOCK, MN—2026-07-06
111528 - MINNESOTA SCREEN PRINT - EMBROIDERY INC
NORWALK, CT—2026-07-06
LAX.COM
NORFOLK, VA—2026-07-01
TEGRA GLOBAL
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343259214.