1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: DIXON INVESTMENTS, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of DIXON INVESTMENTS, INC. in 2523 S. MCDONOUGH RD., ORCHARD HILL, GA 30266 (NAICS 325998). OSHA activity number 343393674.

Watch Dixon Investments, INC. — free Get an email when a new federal OSHA severe-injury report for Dixon Investments, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2523 S. MCDONOUGH RD.
City
ORCHARD HILL
State
GA
ZIP
30266
Mailing
P.O. BOX 510, ORCHARD HILL, GA 30266
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
Employees
39
Ownership type
A

7 citations on file for this inspection.

1910.106 E02 IV D

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $10210.00 · Current $10210.00
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve:  a) Mixing room in building one: On or about August 7, 2018, and at times prior, the employer exposed employees to burn hazards, in that chemicals were not transferred in a closed piping system.
Recent events (1)
  • — Z (S) $10210

1910.178 C02 III

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $13260.00
29 CFR 1910.178(c)(2)(iii): Only approved power-operated industrial trucks designated as EX were not used in atmospheres containing any of the chemicals referenced in this section in quantities sufficient to produce explosive or ignitable mixtures.  a) Building one of establishment: On or about August 7, 2018 and at times prior, the employer exposed employees to burn hazards, in that the Toyota 8FGU25 was not rated for use in a hazardous atmosphere.
Recent events (1)
  • — Z (S) $13260

1910.134 E01

Repeat 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $291.00 · Current $291.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) Mixing room of building one: On or about August 7, 2018, and at times prior, the employer exposed employees to respiratory hazards, in that a medical evaluation was not provided for employees using a 3M full face respirator while mixing chemicals.   Dixon Investments dba ARI, was previously cited for a violation of this occupational safety and health standard or 29 CFR 1910.134(e)(1), which was contained in OSHA inspection number 1064288, citation number 1, item number 1a and was affirmed as a final order on September 28, 2015, with respect to a workplace located at 2523 S. McDonough Road, Orchard, Hill, Georgia.
Recent events (1)
  • — Z (R) $291

1910.134 F02

Repeat 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  a) Mixing room of building one: On or about August 7, 2018, and at times prior, the employer exposed employees to respiratory hazards, in that a fit test was not provided for employees using a 3M full face respirator while mixing chemicals.   Dixon Investments dba ARI, was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.134(f)(2), which was contained in OSHA inspection number 1064288, citation number 1, item number 1b and was affirmed as a final order on September 28, 2015, with respect to a workplace located at 2523 S. McDonough Road, Orchard, Hill, Georgia.
Recent events (1)
  • — Z (R) $0

1910.138 A

Repeat Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $8752.00 · Current $8752.00
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes.  a) Mixing Room of building one: On or about August 7, 2018, and at times prior, the employer exposed employees to chemical hazards, in that impervious gloves were not provided for employees mixing chemicals, such as but not limited to, AlbaChem PSR, pentane, Zeofree 5162, and Methylal Pure Grade.   Dixon Investments d.b.a. ARI, was previously cited for a violation of this occupational safety and health standard , which was contained in OSHA inspection number 1064288, citation number 01, item number 05b and was affirmed as a final order on September 28, 2015, with respect to a workplace located at 2523 S. McDonough Road, Orchard Hill, Georgia.
Recent events (1)
  • — Z (R) $8752

1910.1200 H01

Repeat Gravity 10 1 instance 10 exposed
Issued
Penalty
Initial $20420.00 · Current $20420.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Throughout the establishment: The employer did not provide training specific to the hazards of chemicals used at the establishment to all employees working with hazardous chemicals.  Employees were exposed to hazardous substances such as, but not limited to, AlbaChem PSR, pentane, Zeofree 5162, and Methylal Pure Grade.   Dixon Investments dba ARI, was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.1200(h)(1), which was contained in OSHA inspection number 1064288, citation number 1, item number 8b and was affirmed as a final order on September 28, 2015, with respect to a workplace located at 2523 S. McDonough Road, Orchard, Hill, Georgia.
Recent events (1)
  • — Z (R) $20420

1910.157 C01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) Rear exit door near mixing room:  On or about November 7, 2018, and at times prior, the employer exposed employees to smoke inhalation hazards, in that a portable fire extinguisher was not labeled to identify the location for an employee in case of an emergency.
Recent events (1)
  • — Z (O) $0

View DIXON INVESTMENTS, INC.'s full OSHA safety record →