Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MARTIN CONTRERAS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARTIN CONTRERAS in 1470 KADEN LANE, LOT 77 1460 KADEN LANE, LOT 78, BRASELTON, GA 30517 (NAICS 238130). OSHA activity number 343414819.

Watch Martin Contreras — free Get an email when a new federal OSHA severe-injury report for Martin Contreras is published. One employer, no account, unsubscribe in one click.
Establishment
MARTIN CONTRERAS
Site address
1470 KADEN LANE, LOT 77 1460 KADEN LANE, LOT 78
City
BRASELTON
State
GA
ZIP
30517
Mailing
5291 STATION CIRCLE, NORCROSS, GA 30071
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 3 instances 3 exposed
Issued
Penalty
Initial $3880.00 · Current $3880.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a. On or about 8/24/2018 at 1470 Kaden Lane, Lot 77, Braselton, GA where the employer failed to ensure that workers observed performing framing operations at 19-feet above the lower inside level and 30-feet to the lower outside level were connected on the 6/12 pitch roof.    b. On or about 8/24/2018 at 1460 Kaden Lane, Lot 78, Braselton, GA where the employer failed to ensure that workers observed performing framing operations at 19-feet above the lower concrete level were connected.    c. On or about 8/24/2018 at 1460 Kaden Lane, Lot 78, Braselton, GA where the employer failed to ensure that workers observed performing framing operations at 19-feet above the lower concrete level wore fall protection.
Recent events (3)
  • — A (S) $3880
  • — I (S) $2400
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2772.00 · Current $2772.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    On or about 8/24/2018 at 1470 Kaden Lane, Lot 77, Braselton, GA where the employer failed to ensure that extension ladders were extended 3-feet above the access point exposing workers to fall hazards of 9-feet to the lower level.
Recent events (3)
  • — A (S) $2772
  • — I (S) $1700
  • — Z (S) $2772

1926.1053 B04

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1413.00 · Current $1413.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    On or about 8/24/2018 at 1460 Kaden Lane, Lot 78, Braselton, GA where the employer failed to ensure that step ladders were opened before use exposing workers to fall hazards of up to 6-feet to the lower level.
Recent events (3)
  • — A (S) $1413
  • — I (S) $900
  • — Z (S) $1413

1926.1060 A01

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1060(a)(1): The employer did not provide a training program for each employee using ladders as necessary, enabling each employee to recognize hazards related to ladders and the procedures to be followed to minimize these hazards.  The employer failed to provide ladder training to workers performing construction framing activities where:  a. On or about 8/24/2018 at 1460 Kaden Lane, Lot 78, Braselton, GA where the employer failed to ensure that step ladders were opened before use exposing workers to fall hazards of up to 6-feet to the lower level.  b. On or about 8/24/2018 at 1470 Kaden Lane, Lot 77, Braselton, GA where the employer failed to ensure that extension ladders extended 3-feet above the access point, exposing workers to fall hazards of up to 9-feet to the lower level
Recent events (3)
  • — A (O) $0
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343414819.