Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BONNEVILLE POWER ADMINISTRATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BONNEVILLE POWER ADMINISTRATION in 905 N.E. 11TH AVE., PORTLAND, OR 97232 (NAICS 221121). OSHA activity number 343437026.

Watch Bonneville Power Administration — free Get an email when a new federal OSHA severe-injury report for Bonneville Power Administration is published. One employer, no account, unsubscribe in one click.
Site address
905 N.E. 11TH AVE.
City
PORTLAND
State
OR
ZIP
97232
Mailing
P.O. BOX 3621, PORTLAND, OR 97232
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221121
Employees
400
Ownership type
D

7 citations on file for this inspection.

1910.146 C04

Serious Gravity 10 1 instance 200 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 1480

29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:  a)  On August 10 2018 the employer required employees to enter into permit required spaces such as but not limited to, storage tanks, bus runs and manholes, and had not provided them with an adequate written program that effectively covered all of the required elements of Permit Required Confined Spaces exposing them to hydrogen sulfide.
Recent events (1)
  • — Z (S) $0

1910.146 D02

Serious Gravity 10 1 instance 200 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 1480

29 CFR 1910.146(d)(2): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not identify and evaluate the hazards of permit spaces before employees entered:   a)  On August 10, 2018 the employer did not evaluate the recognized risks that manholes and other similar confined spaces may posed when environmental conditions are present such as but not limited to, organic material that may decay and produce hydrogen sulfide gas which may lead to severe health risks or death when concentrations reach IDLH (immediately dangerous to life and health) concentrations in the enclosed environments such as manholes or vaults.
Recent events (1)
  • — Z (S) $0

1910.146 D03 I

Serious Gravity 10 1 instance 200 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 1480

29 CFR 1910.146(d)(3)(i): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including specifying acceptable entry conditions:  (a)   On August 10, 2018 the employer did not provide employees with clear and consistent instructions that identified confined spaces, such as but not limited to those containing potentially hazardous atmospheres such as hydrogen sulfide gas, as requiring a permit for entry and the measures and procedures that must be recorded and adhered to eliminate and control safety entry into the space; nor adequate training with the means or methods to measure potentially lethal airborne concentrations of hydrogen sulfide that employees may inhale.
Recent events (1)
  • — Z (S) $0

1910.146 D04 I

Serious Gravity 10 1 instance 200 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 1480

29 CFR 1910.146(d)(4)(i): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not ensure that employees used the testing and monitoring equipment properly:  a) On August 10, 2018 the employer did not equip the air monitoring equipment with sensors that would adequately measure the potential risks that may be present when employees entered into spaces such as manholes where potentially dangerous levels of atmospheric hazard such as but not limited to, hydrogen sulfide may have accumulated.
Recent events (1)
  • — Z (S) $0

1910.146 D05 I

Serious Gravity 10 1 instance 200 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 1480

29 CFR 1910.146(d)(5)(i): The employer did not test conditions in the permit space to determine if acceptable entry conditions existed before entry was authorized:  a)  On August 10, 2018 the employer did not provide employees with testing equipment that had the capability of measuring the atmospheric concentration of hydrogen sulfide when they entered into spaces such as but not limited to, manholes, that may contain organic material that can decay and produce potentially hazardous decomposition products that may cause death when inhaled.
Recent events (1)
  • — Z (S) $0

1910.146 G01

Serious Gravity 10 1 instance 200 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 1480

29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:   a)  On August 10 2018 the employer had not provide sufficient or accurate instructions or training to provide sufficient guidance for employees to follow to ensure they entered into confined spaces that potentially pose an inhalation risk to atmospheric hazards such as but not limited to, hydrogen sulfide, that may cause inhalation risk or death.
Recent events (1)
  • — Z (S) $0

1910.146 K02

Serious Gravity 10 1 instance 200 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 1480

29 CFR 1910.146(k)(2): An employer whose employees have been designated to provide permit space rescue and emergency services did not take the measures in accordance with items i-iv of this sub-paragraph:  a)  On August 10 2018 the employer required employees to enter into permit required spaces such as but not limited to, manholes, without the ability to test the atmosphere completely, or without sufficient knowledge to respond to an emergency situation that may contain a hazardous atmosphere leading to death from inhaling lethal concentrations of hydrogen sulfide.
Recent events (1)
  • — Z (S) $0

View BONNEVILLE POWER ADMINISTRATION's full OSHA safety record →