Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROCKBRANCH IRONWORKS, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of ROCKBRANCH IRONWORKS, INC. in 900 S. PINE ST. CENTRALIA JR. HIGH SCHOOL, CENTRALIA, IL 62801 (NAICS 238120). OSHA activity number 343479010.

Watch Rockbranch Ironworks, INC. — free Get an email when a new federal OSHA severe-injury report for Rockbranch Ironworks, INC. is published. One employer, no account, unsubscribe in one click.
Site address
900 S. PINE ST. CENTRALIA JR. HIGH SCHOOL
City
CENTRALIA
State
IL
ZIP
62801
Mailing
11108 POPLAR ST, COULTERVILLE, IL 62237
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
14
Ownership type
A

9 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3789.00 · Current $0.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury:     The employer did not ensure that employees were trained to control or eliminate electrical shock and/or electrocution hazards when using a Lincoln Ranger 250GXT welder (SN:U1180100151).
Recent events (3)
  • — F (S) $0
  • — C (S) $3789
  • — Z (S) $3789

1926.95 A

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $10608.00 Reduced
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided and not used wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    The employer did not ensure that hand protection was used by employees when they were using a Lincoln Ranger 250GXT welder (SN:U1180100151).
Recent events (3)
  • — F (S) $10608
  • — C (S) $13260
  • — Z (S) $13260

1926.351 A02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $10608.00 Reduced
29 CFR 1926.351(a)(2): Current carrying parts of manual electrode holder(s) passing through the gripping portion or the outer surfaces of the jaws were not fully insulated against the maximum voltage encountered to ground:    The employer did not ensure that the electrode holder of a Lincoln Ranger 250GXT welder (SN:U1180100151) was fully insulated when there was approximately one-half (1/2") inch of exposed wire at the bottom of the electrode holder handle.
Recent events (3)
  • — F (S) $10608
  • — C (S) $13260
  • — Z (S) $13260

1926.351 B04

Serious Gravity 10 12 instances 1 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $0.00 Reduced
29 CFR 1926.351(b)(4): Welding cable(s) in use were in need of repair:     The employer did not ensure that welding cables, connected to a Lincoln Ranger 250GXT welder (SN:U1180100151) were properly repaired when they were damaged when:     A.  There was a nick or cut in the electrode cable, approximately eight (8) feet from the welding unit, that had white electrical tape wrapped around it.      B.  There was a nick in the electrode cable, that had exposed wire, approximately eight (8) feet from instance A.    C.  There was a nick or cut in the electrode cable, approximately four (4) feet from instance B, that had gray duct tape wrapped around it.      D.  There was a nick or cut in the electrode cable, approximately two (2) feet from instance C, that had orange electrical tape wrapped around it.      E.  There was a nick or cut in the electrode cable, towards the electrode side from instance D, that had yellow, black and red electrical tape wrapped around it.      F.  There was a nick or cut in the electrode cable, towards the electrode side from instance E, that had yellow and black electrical tape wrapped around it.      G.  There was a nick or cut in the electrode cable, towards the electrode side from instance F, that had black electrical tape wrapped around it.      H.  There was a nick or cut in the electrode cable, towards the electrode side from instance G, that had black electrical tape wrapped around it.      I.  There was a nick or cut in the electrode cable, towards the electrode side from instance H, that had white electrical tape wrapped around it.      J.  There was a nick or cut in the electrode cable, towards the electrode side from instance I, that had blue electrical tape wrapped around it.    K.  There was nick, cut, splice or melted spot in the electrode cable, at the stinger connector, towards the electrode side from instance J, that had black and blue electrical tape wrapped around it.    L.  There was a cut or melted spot in the electrode cable, at the stinger connector, towards the electrode side from instance K, that had an approximately one-quarter (1/4) inch x one-half (1/2) inch section that had exposed bare wire.
Recent events (3)
  • — F (S) $0
  • — C (S) $13260
  • — Z (S) $13260

1910.1200 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3789.00 · Current $3031.00 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):    The employer did not develop and implement a written hazard communication program for employees who were exposed to hazardous chemicals including, but not limited to, Lincoln E7018 welding sticks, Lincoln 6022 Welding sticks and gasoline.
Recent events (3)
  • — F (S) $3031
  • — C (S) $3789
  • — Z (S) $3789

1910.1200 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:    The employer did not ensure that Safety Data Sheets (SDS) were available to employees who were exposed to hazardous chemicals including, but not limited to, Lincoln E7018 welding sticks, Lincoln 6022 Welding sticks and gasoline.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    The employer did not ensure that employees were provided with initial hazard communication information and training when working with hazardous chemicals including, but not limited to, Lincoln E7018 welding sticks, Lincoln 6022 Welding sticks and gasoline.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1904.7 B02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $758.00 · Current $606.00 Reduced
29 CFR 1904.7(b)(2): An injury or illness that resulted in death was not recorded by entering a check mark on the OSHA 300 Log in the space for cases resulting in death.    Rockbranch Ironworks, Coulterville, IL:  On or about 09/20/2018, the employer did not record a death, on the OSHA 300 log for the calendar year of 2018.    On or about 09/20/2018, a fatality occurred when an employee was electrocuted while performing welding operations at a jobsite.  The death was not recorded on the OSHA 300 log.
Recent events (3)
  • — F (O) $606
  • — C (O) $758
  • — Z (O) $758

1904.29 B02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $758.00 · Current $0.00 Reduced
29 CFR 1904.29(b)(2): The employer did not fill out or correctly fill out an OSHA Form 301 or equivalent for each recordable injury or illness.    Rockbranch Ironworks, Coulterville, IL:  On or about 09/20/2018, an OSHA Form 301 or equivalent for the following work-related injuries or illnesses was not filled out or incorrectly filled for the calendar year 2018.     On or about 09/20/2018, a fatality occurred when an employee was electrocuted while performing welding operations at a jobsite and an OSHA 301 was not filled out.
Recent events (3)
  • — F (O) $0
  • — C (O) $758
  • — Z (O) $758

View ROCKBRANCH IRONWORKS, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343479010.