GREENWOOD, ME —
OSHA Inspection: NORTH COUNTRY STEEL
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of NORTH COUNTRY STEEL in 256 MAIN STREET, GREENWOOD, ME 04255 (NAICS 332312). OSHA activity number 343504569.
Where did this inspection happen?
- Establishment
- NORTH COUNTRY STEEL
- Site address
- 256 MAIN STREET
- City
- GREENWOOD
- State
- ME
- ZIP
- 04255
- Mailing
- P.O. BOX 10, GREENWOOD, ME 04255
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 6
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.101 B
- Issued
- Penalty
- Initial $2772.00 · Current $2772.00
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks, were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which was incorporated by reference as specified in 29 CFR 1910.6: Establishment - The compressed gasses in cylinders were not immobilized by chains or other means to prevent them from being knocked over in accordance with Compressed Gas Association Pamphlet P-1-1965.
Recent events (1)
- — Z (S) $2772
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $2772.00 · Current $2772.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: Establishment - Portable fire extinguishers located in the welding areas, near compressed flammable gasses, and close the office were not mounted or identified so that they were readily accessible to employees.
Recent events (1)
- — Z (S) $2772
1910.157 E02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: Establishment - The portable fire extinguishers located in the welding areas, near compressed flammable gasses, and close to the office were not visually inspected at least once a month.
Recent events (1)
- — Z (S) $0
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Establishment - The portable fire extinguishers located in the welding areas, near compressed flammable gasses, and close to the office did not have annual maintenance checks.
Recent events (1)
- — Z (S) $0
1910.178 A04
- Issued
- Abate by
- Penalty
- Initial $2772.00 · Current $2772.00
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: Establishment - An addition was made to the front end of the Komatsu forklift without the manufacturer's prior written approval.
Recent events (1)
- — Z (S) $2772
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): Establishment - The employer did not ensure that the powered industrial truck (forklift) operator was trained and evaluated prior to operating the forklift.
Recent events (1)
- — Z (S) $0
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $2772.00 · Current $2772.00
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a current safety data sheet in the workplace for each hazardous chemical which they use: Establishment - The employer did not have current safety data sheets for the all hazardous chemicals located and used on the property including but not limited to kerosene, unleaded gasoline, and xylene.
Recent events (1)
- — Z (S) $2772
1910.141 D02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: Establishment - The employer did not have hot and cold, or tepid running water in or near the bathrooms.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16 00:00:00
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16 00:00:00
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15 00:00:00
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14 00:00:00
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14 00:00:00
C & S CANOPY, INC.
More inspections in ME
AUGUSTA, ME—2026-07-14 00:00:00
JJ GONZALEZ ROOFING AND GUTTERS
DOVER FOXCROFT, ME—2026-07-14 00:00:00
REDI-ROCK OF CENTRAL MAINE
BENTON, ME—2026-07-13 00:00:00
LEN POULIN, INC.
PORTLAND, ME—2026-07-06 00:00:00
NEW ENGLAND REHABILITATION HOSPITAL OF PORTLAND
DOVER FOXCROFT, ME—2026-07-06 00:00:00
SHAW'S SUPERMARKETS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343504569.