Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WV CLEANERS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WV CLEANERS INC. in 1001 HAL GREER BLVD., HUNTINGTON, WV 25701 (NAICS 812320). OSHA activity number 343570180.

Watch WV Cleaners INC. — free Get an email when a new federal OSHA severe-injury report for WV Cleaners INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WV CLEANERS INC.
Site address
1001 HAL GREER BLVD.
City
HUNTINGTON
State
WV
ZIP
25701
Mailing
1001 HAL GREER BLVD., HUNTINGTON, WV 25701
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812320
Employees
27
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $2070.00 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:    (a)  Steam Presses:  On October 31, 2018 and times prior, the employer has not developed a specific energy control procedure for the Unipress mushroom steam presses for maintenance employees that conduct lockout/tagout on the machine during servicing and maintenance. The mushroom presses has multiple energy sources, 120 volt electrical, 80 psi pneumatic pressure, and 100 psi steam pressure.
Recent events (3)
  • — F (S) $2069.6
  • — C (S) $5174
  • — Z (S) $5174

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:   (a)  Facility Wide: On October 31, 2018 and times prior, employees used energy control procedures when performing service and maintenance of machinery such as, but not limited, to the Unipress mushroom steam presses (120 volt electric, 80 psi pneumatic, 100 psi steam), Multimatic dry cleaning machines (3 phase 240 volt electric), and the Honeywell red eye boiler controller (120 volt electric).  An annual periodic inspection of each energy control procedure and a review of each employee's responsibilities under the energy control procedure was not performed.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Steam Press Area:  On October 31, 2018 and times prior, the employer did not ensure that energy isolating devices were applied to the steam ball valves (100 psi) and the pneumatic ball valve (80 psi) on the Unipress mushroom steam presses during service and maintenance by the authorized employee.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $2070.00 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a)  Dryer Area, North Side:  On October 31, 2018 and times prior to, the employer did not provide machine guarding for the rotating pulleys and moving belts on the back of the American Dryer Corp dryer.    (b) Dryer Area, South Side: On October 31, 2018 and times prior to, the employer did not provide machine guarding for the rotating pulleys and moving belts on the back of the American Dryer Corp dryer.    (c)  Boiler Area:  On October 31, 2018 and times prior the employer did not provide machine guarding for the rotating pulleys and moving belts on the facilitys air compressor.
Recent events (3)
  • — F (S) $2069.6
  • — C (S) $5174
  • — Z (S) $5174

1910.303 G01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $1552.00 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:     (a)  Boiler Area:  On October 31, 2018 and times prior, the area around the 240 volt electrical disconnect and on/off switch for the air compressor was blocked by drums, a dolly, welding cart and other excess materials which did not provide sufficient access and working space.
Recent events (3)
  • — F (S) $1552
  • — C (S) $3880
  • — Z (S) $3880

UNKNOWN

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343570180.