BOISE, ID —
OSHA Inspection: GUERDON ENTERPRISES LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GUERDON ENTERPRISES LLC in 5556 S FEDERAL WAY, BOISE, ID 83716 (NAICS 321991). OSHA activity number 343608568.
Where did this inspection happen?
- Establishment
- GUERDON ENTERPRISES LLC
- Site address
- 5556 S FEDERAL WAY
- City
- BOISE
- State
- ID
- ZIP
- 83716
- Mailing
- 5556 S FEDERAL WAY, BOISE, ID 83716
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321991
- Employees
- 250
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.212 A03 II
- Issued
- Penalty
- Initial $5089.00 · Current $2545.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Mill Shop, on or about November 14, 2018; the Sub Assembly Saw did not have a complete guard. Note: Abatement certification IS NOT required for this item.
Recent events (2)
- — I (S) $2545
- — Z (S) $5089
1910.334 A02 II
- Issued
- Penalty
- Initial $14967.00 · Current $9000.00 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: (a) On or about November 14, 2018 and at times prior thereto; multiple extension cords that had been damaged were in use throughout the facility. Note: Abatement certification IS NOT required for this item. Guerdon Enterprises LLC was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1228739, citation number 1, item number 1 and was affirmed as a final order on July 7, 2017, with respect to a workplace located at 5556 S Federal Way, Boise, ID 83716.
Recent events (2)
- — I (R) $9000
- — Z (R) $14967
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $299.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) On November 16, 2018 and at times prior thereto; the employer did not ensure that inspections of the energy control procedure were conducted at least annually. Note: Abatement certification and documentation ARE required for this item. Guerdon Enterprises LLC was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 957970, citation number 1, item number 1 and was affirmed as a final order on March 7, 2014, with respect to a workplace located at 5556 S Federal Way, Boise, ID 83716.
Recent events (2)
- — I (R) $0
- — Z (R) $299
1910.132 H01
- Issued
- Abate by
- Penalty
- Initial $714.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.132(h)(1): The employer did not provide personnel protective equipment (PPE) at no cost to employees, except as provided by paragraphs(h)(2) through (h)(6) of this section: (a) On November 16, 2018 and at times prior thereto, the employer did not provide safety glasses to employees who were required to wear them. (b) On November 16, 2018 and at times prior thereto, the employer did not provide cut resistive gloves to employees who were required to wear them. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $714
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) On November 16, 2018 and at times prior thereto; the employer did not provide authorized employees (maintenance workers) with the training on the specific lock out procedures for the Giben Routing Table. Also, the employer did not provide the affected employees (equipment operators) with awareness training of the existing lockout procedures and what to do if the Giben Routing Table machine is locked out by an authorized employee. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) On November 16, 2018 and times prior thereto; the employer did not develop and implement a written hazard communication program in the workplace. Employees are exposed to hazardous chemicals including but not limited to PROMAR 200 Zero VOC Interior Latex paint and Hamilton Powdered Wall and Ceiling Texture. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On November 16, 2018 and times prior thereto; the employer did not develop and implement a written hazard communication program in the workplace. Employees are exposed to hazardous chemicals including but not limited to PROMAR 200 Zero VOC Interior Latex paint and Hamilton Powdered Wall and Ceiling Texture. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GUERDON ENTERPRISES LLC
BOISE, ID—2017-04-27 00:00:00
GUERDON ENTERPRISES LLC
BOISE, ID—2014-02-06 00:00:00
GUERDON ENTERPRISES, LLC
SAN JOSE, CA—2012-11-19 00:00:00
GUERDON ENTERPRISES LLC
BOISE, ID—2010-11-01 00:00:00
GUERDON ENTERPRISES, LLC
View GUERDON ENTERPRISES LLC's full OSHA safety record →
More inspections in this industry (NAICS 321991)
LAKE CITY, FL—2026-07-07
TOWNHOMES, LLC.
GREENDALE, IN—2026-06-29
PREMIER MAGNESIA, LLC
LYNNWOOD, WA—2026-06-24
WA317991800 - ADAIR ENTERPRISES LLC
HERMISTON, OR—2026-06-23
317744582 - CMH MANUFACTURING WEST INC
ATWATER, CA—2026-06-22
GLOBAL MODULAR, INC.
More inspections in ID
GOODING, ID—2026-07-10
DAHLGREN INDUSTRIAL INC.
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
MERIDIAN, ID—2026-07-10
DIAMOND CONCRETE, LLC
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
BOISE, ID—2026-07-09
MARK GUHO CONSTRUCTION COMPANY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343608568.