Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EXTERIOR SHEET METAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EXTERIOR SHEET METAL, INC. in CAMP DODGE BUILDING S-4H, JOHNSTON, IA 50131 (NAICS 238160). OSHA activity number 343677225.

Watch Exterior Sheet Metal, INC. — free Get an email when a new federal OSHA severe-injury report for Exterior Sheet Metal, INC. is published. One employer, no account, unsubscribe in one click.
Site address
CAMP DODGE BUILDING S-4H
City
JOHNSTON
State
IA
ZIP
50131
Mailing
1101 N. MAIN STREET, GRIMES, IA 50111
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
23
Ownership type
A

5 citations on file for this inspection.

1926.20 B02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3543.00 · Current $0.00 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person (i.e., a person who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has the authorization to take prompt corrective measures to eliminate them).  (a) On or about 20 December 2018, the employer did not provide for frequent and regular inspections of the jobsite in that: 1) Employees were exposed to hazards associated with falls from roofs. 2) Employees were exposed hazards associated with fall hazards from aerial lifts. 3) Employees were exposed to hazards associated with falling objects.  Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos, which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $3543

1926.100 A

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2125.00 · Current $0.00 Reduced
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:  On or about 20 December 2018, an employee operating an aerial lift while installing sheet metal siding was exposed to possible head injury from impact and falling objects. The exposed employee was working directly under another employee that was utilizing portable drills/screw guns and other materials.  Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos, which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2125

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3543.00 · Current $3543.00
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: Note:  As of January 1, 1998, subpart M of this part (1926.502(d), provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated.    On or about 20 December 2018, an employee working from a JLG aerial lift installing sheet metal on a parapet approximately 16 feet above the lower level, was not protected from falls by a personal fall arrest system.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos, which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $3543
  • — Z (S) $3543

1926.501 B11

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3543.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:    On or about 20 December 2018, an employee installing sheet metal flashing along a parapet approximately 16 feet from the lower level, was not protected from falls by a guardrail, safety net, or personal fall arrest system.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos, which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $3543

1926.503 A02 VIII

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $3543.00 · Current $0.00 Reduced
29 CFR 1926.503(a)(2)(viii): The employer did not assure that each employee had been trained by a competent person qualified in the standards contained in subpart M:  The employer did not assure that each employee had been trained by a competent person qualified in the standards contained in subpart M, in that there was no anchor point installed on the roof and employees were instructed to tie off to the aerial lift as a means of fall protection from the roof.  Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos, which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $3543

View EXTERIOR SHEET METAL, INC.'s full OSHA safety record →