2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: LOPEZ ROOFING SERVICES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LOPEZ ROOFING SERVICES, LLC in (LOT #109) 617 WYNNEVIEW COURT, POWDER SPRINGS, GA 30127 (NAICS 238160). OSHA activity number 343732871.

Watch Lopez Roofing Services, LLC — free Get an email when a new federal OSHA severe-injury report for Lopez Roofing Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
(LOT #109) 617 WYNNEVIEW COURT
City
POWDER SPRINGS
State
GA
ZIP
30127
Mailing
381 CANTON STREET, CANTON, GA 30114
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles:  (a) New residential construction located on Lot #109, Roof: On or about 01/23/2019, and at times prior, the employer exposed employees to struck-by hazards while operating Hitachi roofing nail guns, in that protective eyewear was not provided to employees engaged in shingle installation as these nailers were being operated at 120 PSI.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1926.501 B13

Serious Gravity 10 2 instances 5 exposed
Issued
Penalty
Initial $3978.00 · Current $2387.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   (a) New residential construction located on Lot #109, Upper roof: On or about 01/23/2019, and at times prior, the employer exposed employees to falls of 21-feet, 7-inches to the lower level, in that a fall protection system was not provided to employees engaged in roofing activities on a 6/12 pitched roof.   (b) New residential construction located on Lot #109, Rear lower roof: On or about 01/23/2019, and at times prior, the employer exposed employees to falls of 11-feet to the lower level, in that a fall protection system was not provided to employees engaged in roofing activities on a 6/12 pitched roof.
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

View LOPEZ ROOFING SERVICES, LLC's full OSHA safety record →