CAMERON, IL —
OSHA Inspection: MICHAEL HAUN
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MICHAEL HAUN in 2211 155TH STREET, CAMERON, IL 61423 (NAICS 314910). OSHA activity number 343737862.
Where did this inspection happen?
- Establishment
- MICHAEL HAUN
- Site address
- 2211 155TH STREET
- City
- CAMERON
- State
- IL
- ZIP
- 61423
- Mailing
- PO BOX 1382, GALESBURG, IL 61402
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 314910
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $3410.00 · Current $2045.00 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): The employer did not ensure exit route(s) were kept free and unobstructed: On or about January 25, 2019, employees were exposed to fire hazards when working in the Sewing Room and the employer had installed a partition in the exit route.
Recent events (2)
- — I (S) $2045
- — Z (S) $3410
1910.141 D02 II
- Issued
- Abate by
- Penalty
- Initial $1705.00 · Current $1020.00 Reduced
General-duty citation text
29 CFR 1910.141(d)(2)(ii): The employer did not ensure lavatories were provided with hot and cold, or tepid running water: On or about January 25, 2019, employees were exposed to bacteria and viruses and the employer had not provided hot and cold running water for handwashing purposes.
Recent events (2)
- — I (S) $1020
- — Z (S) $1705
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $2273.00 · Current $1365.00 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): The employer did not ensure portable fire extinguishers were subjected to an annual maintenance check: On or about January 25, 2019, employees were exposed to fire hazards while working in the Fabrication and Sewing Rooms and the employer had not ensured fire extinguishers were given an annual maintenance inspection.
Recent events (2)
- — I (S) $1365
- — Z (S) $2273
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $2385.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): The employer permitted flexible cords and/or cables be used as a substitute for the fixed wiring of a structure: On or about January 25, 2019, employees were exposed to electrical shock hazards when working in the Fabrication and Sewing Rooms and because flexible cords and extension cords were being used as a substitute for fixed wiring.
Recent events (2)
- — I (S) $2385
- — Z (S) $3978
1910.305 G01 IV C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): The employer permitted flexible cords and cables be run through doorways, windows, or similar openings: On or about January 25, 2019, employees were exposed to electrical shock hazards when working in the Old School Building because a flexible cord was run through the door of the restroom.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): The employer did not ensure flexible cords were not attached to building surfaces: On or about January 25, 2019, employees were exposed to electrical shock hazards when working in Fabrication and Sewing Building and flexible cords were attached to the wooden ceiling joists with bent nails.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 II
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $2385.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): The employer did not ensure flexible cords were used only in continuous lengths without splice or tap: On or about January 25, 2019, employees were exposed to fire hazards in the Fabrication Room and Old School Buildings and flexible cords and were run through adapters and plugged into one another.
Recent events (2)
- — I (S) $2385
- — Z (S) $3978
More inspections in this industry (NAICS 314910)
TAMAQUA, PA—2026-05-05
MAINSTREET MANUFACTURING COMPANY LLC
TAMAQUA, PA—2026-03-30
MAINSTREET MANUFACTURING COMPANY LLC
FORT LAUDERDALE, FL—2026-01-28
INDUSTRIAL SHADEPORTS, INC.
SPRING, TX—2026-01-22
AAA CANVAS & AWNING CO., INC.
ROMULUS, MI—2025-12-19
DETROIT TARPAULIN & REPAIR SHOP INC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source