SYRACUSE, NY —
OSHA Inspection: LANCE DECKER
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LANCE DECKER in 1711 WEST GENESEE STREET, SYRACUSE, NY 13204 (NAICS 238160). OSHA activity number 343763686.
Where did this inspection happen?
- Establishment
- LANCE DECKER
- Site address
- 1711 WEST GENESEE STREET
- City
- SYRACUSE
- State
- NY
- ZIP
- 13204
- Mailing
- 428 CHURCH STREET, NORTH SYRACUSE, NY 13212
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $2273.00 · Current $160.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 2/5/2019, Roof of 1711 West Genesee St: Employees performing ground work, below the eaves and rake of roofing project were not provided with nor wearing any head protection. Abatement certification is required for this item.
Recent events (3)
- — J (S) $160
- — C (S) $2273
- — Z (S) $2273
1926.404 B01 II
- Issued
- Abate by
- Penalty
- Initial $2273.00 · Current $160.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection: a) On or about 2/5/2019, Worksite at 1711 West Genesee St: Employees were utilizing electrical powered equipment such as, but not limited to a compressor and a circular saw. These pieces of equipment were energized through an extension cord plugged into a wall outlet, none of which were protected by or equipped with a ground fault circuit interrupter. Abatement certification is required for this item.
Recent events (3)
- — J (S) $160
- — C (S) $2273
- — Z (S) $2273
1926.405 J01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported: a) On or about 2/5/2019, Worksite at 1711 West Genesee St: Employees were utilizing electrical powered equipment such as, but not limited to a compressor and a circular saw. These pieces of equipment were energized through an extension cord which had a metal receptacle box attached to the end of the cord. The box was designed to be mounted, and was not secured. Abatement certification is required for this item.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.404 F06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 2/5/2019, Worksite at 1711 West Genesee St: Employees were utilizing a yellow colored air compressor which was lacking its ground pin, and had no continuous path to ground. Abatement certification is required for this item.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.501 B04 I
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $160.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a) On or about 2/5/2019, Roof of 1711 West Genesee St: Employees performing roofing work next to skylights were not utilizing any fall protection. Employees exposed to falls of over 22 feet. Abatement documentation is required for this item.
Recent events (3)
- — J (S) $160
- — C (S) $3978
- — Z (S) $3978
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) On or about 2/5/2019, Roof of 1711 West Genesee St: Employees performing roofing work on a low slope roof were not utilizing any fall protection. Employees exposed to falls of over 22 feet. Abatement documentation is required for this item.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $160.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about 2/5/2019, Roof of 1711 West Genesee St: Employees performing roofing work, exposed to falls of over 22 feet, were not provided with any training in regards to the recognition and avoidance of fall hazards, and the use of fall protection. Abatement certification is required for this item.
Recent events (3)
- — J (S) $160
- — C (S) $2842
- — Z (S) $2842
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $160.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 2/5/2019, Roof of 1711 West Genesee St: Employees were accessing and egressing a roof with an eave to ground height of 22 feet. The ladders side rails only extended 1.5 feet. Abatement certification is required for this item.
Recent events (3)
- — J (S) $160
- — C (S) $2842
- — Z (S) $2842
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16 00:00:00
MARVIN PINERA
CARSON CITY, NV—2026-07-16 00:00:00
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16 00:00:00
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16 00:00:00
CARLOS CHE
BALTIMORE, MD—2026-07-16 00:00:00
VAL CONSTRUCTION INC
More inspections in NY
MAYVILLE, NY—2026-07-16 00:00:00
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16 00:00:00
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16 00:00:00
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15 00:00:00
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15 00:00:00
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343763686.