NORTH CHARLESTON, SC —
OSHA Inspection: CARVER MARITIME, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CARVER MARITIME, LLC in 1400 PIERSIDE STREET BUILDING 190, SUITE D, NORTH CHARLESTON, SC 29405 (NAICS 488320). OSHA activity number 343792032.
Where did this inspection happen?
- Establishment
- CARVER MARITIME, LLC
- Site address
- 1400 PIERSIDE STREET BUILDING 190, SUITE D
- City
- NORTH CHARLESTON
- State
- SC
- ZIP
- 29405
- Mailing
- 1400 PIERSIDE STREET BUILDING 190, SUITE D, NORTH CHARLESTON, SC 29405
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488320
- Employees
- 35
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.304 G05
- Issued
- Penalty
- Initial $4831.00 · Current $2899.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) South end of Warehouse Building #79: The 120 volt electrical cord to a barrel fan used on a work platform was missing the ground pin. b) South end of Warehouse Building #79: A yellow in color 120 volt extension cord used to power the barrel fan's electrical cord, was missing the ground pin.
Recent events (2)
- — I (S) $2898.6
- — Z (S) $4831
1917.122 C
- Issued
- Penalty
- Initial $6440.00 · Current $3864.00 Reduced
General-duty citation text
29 CFR 1917.122(c): Clear passages to the exits were not maintained.: a) Warehouse Building #79: A wall of several feet high of bags filled with sweet potato pellets compleletly blocked off access to the exit door at the north end of the 250 foot long building.
Recent events (2)
- — I (S) $3864
- — Z (S) $6440
1910.303 G01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: Southeast corner of Warehouse #79: A cut-off switch to a 120 volt electrical panel box used to control lighting and receptacle outlets was blocked by storage consisting of discarded portable fire extinguishers, a barrel floor fan, cardboard boxes full of miscellanies items, wooden skids, and other debris.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV C
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows, floors, or similar openings. a) Warehouse Building #79 - Supervisor's office West side window: A 120 volt extension cord ran from a power strip inside the office through a hole cut into the window screen and to the elevated platform where it supplied power to the barrel fan.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.334 A02 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) South end of the Warehouse Building #79: The 120 volt cord to a barrel fan had the outer insulation pulled back from the plug-end exposing 1/2 inch of the three individual insulated wires.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at CARVER MARITIME, LLC
NORTH CHARLESTON, SC—2023-05-03 00:00:00
CARVER MARITIME, LLC
NORTH CHARLESTON, SC—2023-05-03 00:00:00
CARVER MARITIME, LLC
NORTH CHARLESTON, SC—2019-06-05 00:00:00
CARVER MARITIME, LLC
View CARVER MARITIME, LLC's full OSHA safety record →
More inspections in this industry (NAICS 488320)
MARATHON, FL—2026-07-14
DISCOUNT ROCK & SAND, INC.
RIVIERA BEACH, FL—2026-07-07
PORT CONTRACTORS SOUTHEAST, LLC
JACKSONVILLE, FL—2026-07-01
CROWLEY LINER SERVICES
SEATTLE, WA—2026-06-30
WA317991873 - SSA TERMINALS LLC
TERMINAL ISLAND, CA—2026-06-10
YUSEN TERMINALS LLC
More inspections in SC
CHARLESTON, SC—2026-07-15
U.S. DEPT OF TRANSPORTATION
COLUMBIA, SC—2026-07-15
77574 - PRECOAT METALS
NORTH CHARLESTON, SC—2026-07-14
DETYENS SHIPYARDS, INC.
GREENVILLE, SC—2026-07-09
77570 - SHARPSHOOTERS INDOOR RANGE INC
NORTH CHARLESTON, SC—2026-07-09
77569 - RAYCAP INC
Source