Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TONY'S PIZZERIA

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TONY'S PIZZERIA in 1916 KINGSTOWN RD., WAKEFIELD, RI 02879 (NAICS 722210). OSHA activity number 343834099.

Watch Tony'S Pizzeria — free Get an email when a new federal OSHA severe-injury report for Tony'S Pizzeria is published. One employer, no account, unsubscribe in one click.
Establishment
TONY'S PIZZERIA
Site address
1916 KINGSTOWN RD.
City
WAKEFIELD
State
RI
ZIP
02879
Mailing
1916 KINGSTOWN RD., WAKEFIELD, RI 02879
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722210
Employees
17
Ownership type
A

9 citations on file for this inspection.

1910.141 A03 III

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $0.00 Reduced
29 CFR 1910.141(a)(3)(iii): Floor(s), working place(s), and passageway(s) were not kept free from protruding nails, splinters, loose boards, and unnecessary holes and openings to facilitate cleaning:    (a) In the basement bathroom:  On or about 3/7/19 the bathroom floor had two holes covered with wet cardboard and multiple layers of rubber matting.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2273

1910.151 C

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3031.00 · Current $0.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    (a) At the establishment:  On or about 3/7/2019, employees were exposed to an injurious corrosive material (First Mark, Germicidal Ultra Bleach), without suitable facilities for quick drenching or flushing of the eyes and body within the work area for immediate emergency use.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3031

1910.303 B02

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4546.00 · Current $3182.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) On the shelf outside the basement bathroom:  On or about 3/7/2019, a power strip connected to an extension cord was used to charge portable car signs.    (b) In the ceiling rafters of the basement:  On or about 3/7/2019, a power strip connected to an extension cord was used to supply power to permanent lighting.
Recent events (2)
  • — I (S) $3182
  • — Z (S) $4546

1910.304 B03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(b)(3)(i): A single 125-volt, single-phase, 15- and 20-ampere receptacle installed in a bathroom did not have a ground-fault circuit-interrupter protection for personnel:  (a) In the basement bathroom:  On or about 3/7/2019, the receptacle next to the bathroom sink did not have a ground-fault-circuit-interrupter installed, creating a shock hazard to employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  (a) In the storage area of the basement:  On or about 3/7/2019, the employer did not ensure that the junction box on the south basement wall was covered to prevent accidental contact.  (b) In the basement bathroom:  On or about 3/7/2019, the employer allowed a wall socket receptacle in the bathroom to be used to plug the bathroom lights into and run an extension cord under the door to a rack of rechargeable car signs, while the wall socket receptacle did not have a cover, creating an electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV C

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through dorways, windows or floors:  (a) In the basement bathroom:  On or about 3/7/2019, an extension cord was run under the bathroom door to a power strip to allow charging of the mobile electric car signs.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1591.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a) At the establishment:  On or about 3/7/2019, the employer did not develop and maintain a written chemical hazard communication program.
Recent events (2)
  • — I (S) $1591
  • — Z (S) $2273

1910.1200 G08

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):    (a) At the establishment:  On or about 3/7/2019, the employer did not maintain copies of the required safety data sheets and did not ensure that they were readily accessible to employees, for the hazardous chemicals that were on hand.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    (a) At the establishment:  On or about 3/7/2019, the employer had not provided training on the hazardous chemicals in the work area to employees.