1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ER SNELL CONTRACTOR, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ER SNELL CONTRACTOR, INC. in 5601 COLUMBIA ROAD, GROVETOWN, GA 30813 (NAICS 324121). OSHA activity number 343943536.

Watch ER Snell Contractor, INC. — free Get an email when a new federal OSHA severe-injury report for ER Snell Contractor, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5601 COLUMBIA ROAD
City
GROVETOWN
State
GA
ZIP
30813
Mailing
5102 PIERCE CT, EVANS, GA 30809
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324121
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.28 B01 I

Deleted Serious Gravity 10 2 instances 4 exposed
Issued
Penalty
Initial $13260.00 · Current $0.00 Reduced
29 CFR 1910.28(b)(1)(i): Each employee on a walking/working surface having an unprotected side or edge which was four feet (1.2m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.                                                                                                           On or about 4/18/19 at the platform silo area located at 5601 Columbia Road, Grovetown, GA: Employees performing servicing and maintenance activities on the chain drive equipment and drum equipment were exposed to a fall hazard in excess of 100-feet, where the employer failed to install a guardrail system and or ensure the employees used a fall arrest system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

1910.147 C04 II

Serious Gravity 10 8 instances 4 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $10000.00 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):    On or about 4/18/19 at 5601 Columbia Road, Grovetown, GA: Employees performing servicing and maintenance activities on concrete manufacturing equipment were exposed to caught-in and crushing hazards, in that no specific written procedures were developed to control the mechanical, rotating, and gravitational energy sources such as, but not limited to the cold feed, screen deck, incline conveyor to drum, drum, dragline, bag house, silo, and components asphalt manufacturing equipment.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $13260

1910.147 C07 I

Serious Gravity 10 8 instances 4 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $10000.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    On or about 4/18/19 at 5601 Columbia Road, Grovetown, GA: Employees performing servicing and maintenance activities on concrete manufacturing equipment were exposed to caught-in and crushing hazards, in that they were not aware of the mechanical, rotating, and gravitational energy sources or how to isolate the sources in equipment such as but not limited to cold feed, screen deck, incline conveyor to drum, drum, dragline, bag house, silo, and components asphalt manufacturing equipment.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $13260

View ER SNELL CONTRACTOR, INC.'s full OSHA safety record →