OSHA Inspection: FISH AND WILDLIFE SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FISH AND WILDLIFE SERVICE in TETLIN NATIONAL WILDLIFE REFUGE P.O. BOX 779, TOK, AK 99780 (NAICS 924120). OSHA activity number 343961041.

Watch Fish AND Wildlife Service — free Get an email when a new federal OSHA severe-injury report for Fish AND Wildlife Service is published. One employer, no account, unsubscribe in one click.
Site address
TETLIN NATIONAL WILDLIFE REFUGE P.O. BOX 779
City
TOK
State
AK
ZIP
99780
Mailing
TETLIN NATIONAL WILDLIFE REFUGE P.O. BOX 779, TOK, AK 99780
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
15
Ownership type
D

23 citations on file for this inspection.

1910.28 B01 I A

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.28(b)(1)(i)(A): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling by a standard guardrail system.  Headquarters shop; on or about 23 April 2019 and times prior thereto; two instances were noted where the employer did not provide guardrails across the mezzanine storage areas:       Instance a. Mezzanine situated between bay one and the back man-door. The employer did not provide guardrails across a 28-foot long mezzanine, measuring 105-inches above the lower floor.       Instance b. Mezzanine situated adjacent to the environmental education area. The employer did not provide guardrails across a 48-foot long mezzanine, measuring 84-inches above the lower floor.  This condition exposed employees to a fall hazard.
Recent events (1)
  • — Z (S) $0

1910.37 A04

Serious Gravity 1 2 instances 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times.  Tetlin Facilities; on or about 23 April 2019 and times prior thereto; two instances were noted where emergency exit lighting was inoperative or unavailable:       a) Headquarters shop North door, installed emergency exit lights inoperative.        b) Throughout the Hangar building, no emergency exit lighting is available.   This condition exposed employees to delays in exiting the building and smoke inhalation, fire, and tripping hazards.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Serious Gravity 1 5 instances 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit".  Headquarters Garage and Hangar; on or about 23 April 2019 and times prior thereto; five instances were noted where exit signs were not posted along the exit route.               a. Headquarters garage, back door; exit sign was not posted.         b. Hangar wood shop area; exit sign was not posted.              c. Hangar welding area; exit sign was not posted.        d. Hangar aircraft storage area North corner; exit sign was not posted.        e. Hangar aircraft storage area South corner; exit sign was not posted.   This condition exposed employees to delays in exiting the building and smoke inhalation, fire, and tripping hazards.
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving.  Hangar wood shop area; on or about 23 April 2019 and times prior thereto; the employer did not ensure that the Grizzly 12-Speed, 17-inch Floor Drill Press, Serial number 11302, model G7947, was securely mounted to prevent movement. This condition exposed employees to a struck by hazard.
Recent events (1)
  • — Z (S) $0

1910.213 J03

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(j)(3): Hand-fed jointer(s) with horizontal cutting head(s) did not have automatic guard(s) which automatically adjusted to cover the unused portion of the head and/or remained in contact with the material at all times.  Hangar woodshop area; on or about 23 April 2019 and times prior thereto; a Grizzly 8-inch Spiral Cutterhead Jointer, serial number 80505969, model G0593, did not have the protective guard installed. This condition exposed employees to a caught in hazard.
Recent events (1)
  • — Z (S) $0

1910.213 C02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator.  Hangar woodshop area; on or about 23 April 2019 and times prior thereto; the employer did not ensure that the spreader was installed on the Grizzly 10-inch table saw, serial number 724751, model G1023SLX. This condition exposed employees to a struck by hazard.
Recent events (1)
  • — Z (S) $0

1910.213 C03

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator.  Hangar woodshop area; on or about 23 April 2019 and times prior thereto; the employer did not ensure that the kickback fingers were installed on the Grizzly 10-inch table saw, serial number 724751, model G1023SLX. This condition exposed employees to a struck by hazard.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  Hangar woodshop and welding areas; on or about 23 April 2019 and times prior thereto; flexible cords were used as a substitute for fixed wiring. Two instances were noted:       a. Woodshop area; an energized 25-foot black heavy duty, 14/2 gauge extension cord was used a fixed wiring. Extension cord was wired directly into a four-place service box. Cord is used to power Grizzly jointer.        b. Welding area; an energized 25-foot black medium duty extension cord was wired directly to an electrical switch box.   This condition exposed employees to electrical shock and electrical burn hazards.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.  Hangar woodshop area; on or about 23 April 2019 and times prior thereto; strain relief was not provided on an energized 25-foot heavy duty black extension cord. This condition exposed employees to electrical shock and electrical burn hazards.
Recent events (1)
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).  Headquarters shop, bay one; the employer did not ensure that portable cord and plug equipment was inspected prior to use. A Master 55,000 BTU Thermostat had damage to the power cord outer protective jacket. This condition exposed employees to electrical shock and electrical burn hazards.
Recent events (1)
  • — Z (S) $0

1910.1200 F05 II

Serious Gravity 1 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings.  Hangar outside adjacent to the building; on or about 23 April 2019 and times prior thereto; two instances were noted where 500-gallon single wall steel tanks, were not marked indicating the contents:        a. North side of the building; a single wall 500-gallon steel tank was not marked with hazard warnings.       b. South side of the building; a single wall 500-gallon steel tank was not marked with hazard warnings.  This exposed employees to contact with combustible liquids and other fire hazards.
Recent events (1)
  • — Z (S) $0

1904.32 A04

Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30.  Tetlin Wildlife Refuge; on or about 23 April 2019 and times prior thereto; the employer did not ensure that the OSHA 300A Summary of Work-related Injuries and Illness Log or its equivalent was posted. This condition leads to inaccurate reporting of injuries and illnesses.
Recent events (1)
  • — Z (O) $0

1910.151 C

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.151(c): Where the eyes of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes were not available for immediate emergency use.  Hangar aircraft storage side; on or about 23 April and times prior thereto; the Sperian, emergency eyes wash station was blocked. A metal trash can, step-ladder and plastic barrel were stored in front of the station impeding access. This condition exposed employees to eye trauma hazards.
Recent events (1)
  • — Z (O) $0

1910.157 C01

Other-than-serious 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  Throughout Hangar; on or about 23 April 2019 and times prior thereto; portable fire extinguisher were not mounted. Four instances were noted:       a. Hangar woodshop area; a Amerex Model B456, Serial number BE-652429, ABC Dry chemical fire extinguisher was not mounted.          b. Hangar welding area, work bench; a Amerex Model B456, Serial number E-94083431, ABC Dry chemical fire extinguisher was not mounted.          c. Hangar aircraft side; a Buckeye, Model 10HI SA80, Serial number XJ-968595, ABC Dry chemical fire extinguisher was not mounted.         d. Hanger aircraft side, adjacent to eyewash station; Amerex Model B456, Serial number E-82265791, ABC Dry chemical fire extinguisher was not mounted.  This condition exposed employees to a fire hazard.
Recent events (1)
  • — Z (O) $0

1910.157 E02

Other-than-serious 8 instances 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly.  Throughout Tetlin National Wildlife Refuge Facilities; on or about 23 April 2019 and times prior thereto; portable fire extinguishers were not inspected at least monthly. Eight instances were noted:       a. Administrative building adjacent to main entrance; a First Alert Model FE4A60B, serial number G-523178, Multipurpose Dry Chemical Fire Extinguisher. Last inspection December 2018.       b. Administrative building conference room; a First Alert Model FE4A60B, serial number J-801589, Multipurpose Dry Chemical Fire Extinguisher. Last inspection indicated December 2018.       c. Headquarters Shop adjacent to bay 1; A Amerex, Model B456, Serial number B-76359508, ABC Dry chemical fire extinguisher. Last inspection indicated  August 2016.       d. Hangar woodshop area; a Amerex Model B456, Serial number BE-652429, ABC Dry chemical fire extinguisher. Last inspection indicated June 2018.       e. Hangar welding area, work bench; a Amerex Model B456, Serial number E-94083431, ABC Dry chemical fire extinguisher. Last inspection indicated June 2018.       f. Hangar welding area stanchion; a Amerex Model B456, Serial number BE-667319, ABC Dry chemical fire extinguisher. Last inspection unknown.       g. Hangar aircraft side; a Buckeye, Model 10HI SA80, Serial number XJ-968595, ABC Dry chemical fire extinguisher. Last inspection indicated March 2016.       h. Hanger aircraft side, adjacent to eyewash station; Amerex Model B456, Serial number E-82265791, ABC Dry chemical fire extinguisher. Last inspection unknown.  This condition exposed employees to a fire hazard.
Recent events (1)
  • — Z (O) $0

1910.157 E03

Other-than-serious 6 instances 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  Throughout Tetlin National Wildlife Refuge Facilities; on or about 23 April 2019, portable fire extinguishers were not inspected annually. Six instances were noted:       a. Administrative building adjacent to main entrance; a First Alert Model FE4A60B, serial number G-523178, Multipurpose Dry Chemical Fire Extinguisher. Last annual inspection indicated 2015.       b. Administrative building conference room; a First Alert Model FE4A60B, serial number J-801589, Multipurpose Dry Chemical Fire Extinguisher. Last annual inspection indicated 2015.       c. Headquarters Shop adjacent to bay 1; A Amerex, Model B456, Serial number B-76359508, ABC Dry chemical fire extinguisher. Last annual inspection indicated 2016.       d. Hangar woodshop area; a Amerex Model B456, Serial number BE-652429, ABC Dry chemical fire extinguisher. Last annual inspection indicated 2012.       e. Hangar welding area stanchion; a Amerex Model B456, Serial number BE-667319, ABC Dry chemical fire extinguisher. Last annual inspection indicated 2012.       f. Hangar aircraft side; a Buckeye, Model 10HI SA80, Serial number XJ-968595, ABC Dry chemical fire extinguisher. Last annual inspection unknown.  This condition exposed employees to a fire hazard.
Recent events (1)
  • — Z (O) $0

1910.303 F02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.  Headquarters cold storage area; on or about 23 April 2019 and times prior thereto; an energized 8-place, 120 volt, rainproof circuit breaker panel, model CH8L125RP Type 3R;  was not labeled with all circuits installed. This condition exposed employees to electrical shock and electrical burn hazards.
Recent events (1)
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage.  Hanger woodshop area; on or about 23 April 2019 and times prior thereto; the employer did not ensure that the electrical panel administratively labeled "A" was readily accessible in the event of an electrical emergency. This condition exposed employees to an electrical shock and electrical burn hazards.
Recent events (1)
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.   Hangar aircraft storage area; on or about 23 April 2019 and times prior thereto, a 24-place electrical panel administratively labeled "B" was missing a knockout on the lower left side. This condition exposed employees to fire, electrical shock and electrical burn hazards.
Recent events (1)
  • — Z (O) $0

1910.1030 G01 I A

Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1030(g)(1)(i)(A): Warning labels were not affixed to containers of regulated waste, refrigerators, or freezers containing blood or other potentially infectious material.  Headquarters shop biological specimen storage refrigerator; on or about 23 April 2019 and times prior thereto; the GE Refrigerator used to store biological specimens did not have warning labels affixed. This condition exposed employees to biological hazards.
Recent events (1)
  • — Z (O) $0

1910.1200 G08

Other-than-serious 2 instances 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical in the workplace.  Headquarters Shop; on or about 23 April 2019 and times prior thereto; the employer did not ensure that Safety Data Sheets for each hazardous chemical located in the workplace was readily accessible. Two instances were noted:       a. Goo Gone All Purpose Cleaner, 24 oz. was not available.       b. NAPA CRC QD Electronic Cleaner, 11 oz. was not available.  This condition exposed employees to chemical burns, irritation of the eyes and upper respiratory tract, and skin dermatitis hazards.
Recent events (1)
  • — Z (O) $0

1960.12 C01

Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1960.12(c)(1): 29 CFR 1960.12(c)(1): The Agency did not post details of the procedures for responding to reports by employees of unsafe or unhealthful working conditions.  Administrative office; on or about 23 April 2019 and times prior thereto, the employer did not ensure that the agency unsafe and unhealthful working conditions poster was posted. This condition exposed employees to inadequate instruction.
Recent events (1)
  • — Z (O) $0

1960.55 A

Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1960.55(a):  The Agency did not provide safety and health training for supervisory employees.  Administrative office; on or about 23 April 2019 and times prior thereto; the employer did not provide supervisor safety training for assigned supervisors to enable supervisors to recognize and eliminate, or reduce, occupational safety and health hazards in their working units. This condition exposed employees to inadequate instruction, orientation and/or training.
Recent events (1)
  • — Z (O) $0

View FISH AND WILDLIFE SERVICE's full OSHA safety record →