1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: FISH AND WILDLIFE SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FISH AND WILDLIFE SERVICE in KODIAK NATIONAL WILDLIFE REFUGE 1390 BUSKIN RIVER ROAD, KODIAK, AK 99615 (NAICS 924120). OSHA activity number 344210034.

Watch Fish AND Wildlife Service — free Get an email when a new federal OSHA severe-injury report for Fish AND Wildlife Service is published. One employer, no account, unsubscribe in one click.
Site address
KODIAK NATIONAL WILDLIFE REFUGE 1390 BUSKIN RIVER ROAD
City
KODIAK
State
AK
ZIP
99615
Mailing
NATIONAL WILDLIFE REFUGE 1390 BUSKIN RIVER ROAD, KODIAK, AK 99615
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
15
Ownership type
D

7 citations on file for this inspection.

1910.36 D03

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.36(d)(3): An exit route door may be locked from the inside only in mental, penal, or correctional facilities and then only if supervisory personnel are continuously on duty and the employer has a plan to remove occupants from the facility during an emergency.  Buskin River Road, Administrative Building, Southern Emergency Exit Door: on or about 30 July 2019, an emergency exit door was locked from the inside by a deadbolt style lock. This condition exposed employees to delays in exiting the building and hazards associated with smoke inhalation and burns from fire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.36 H03

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.36(h)(3): Outdoor exit route(s) were not reasonably straight and did not have smooth, solid, substantially level walkways:  Buskin River Road, Administrative Building, southern emergency exit: on or about 30 July 2019, overgrown brush measuring approximately 48 inches in height and 36 inches width was present on the exterior pathway of an emergency exit route. This condition exposed employees to hazards associated with trips or falls due to walkways not being smooth and substantially level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 A03

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(3): Exit routes were not kept free and unobstructed. Materials or equipment were placed, either permanently or temporarily, within the exit route:  On or about 30 July 2019, exit routes were blocked in two instances obstructing the path of travel.  A) Buskin River Road, Administrative Building, southern facing emergency exit adjacent to Bill's office: a coat rack and storage container were placed in the doorway blocking the path of travel.   B) Buskin River Road, Maintenance Shop: a portable step ladder was placed in the doorway leading from the maintenance shop through the boat shop to an emergency exit blocking the path of travel.   These conditions exposed employees to delays in exiting the building and hazards associated with smoke inhalation and burns from fire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 D02 I

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(2)(i): Approved containers and/or portable tanks were not used for the storage of flammable liquids:   Buskin River Road, fuel shed: On or about 30 July 2019; 5 gallon plastic fuel storage containers were used to transport and store fuel. This condition exposed employees to hazards associated with fire and smoke.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.110 F02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.110(f)(2)(i): Portable LP-Gas containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons:  Buskin River Road, Maintenance Building: On or about 30 July 2019; a 100 pound propane tank was stored outside and not protected from contact with motorized vehicles. This condition exposed employees to contact with flammable and combustible liquids and other fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  Buskin River Road, Maintenance Shop: on or about 30 July 2019, the employer did not ensure that the Rockwell drill press, serial number 1786442, was securely mounted to prevent movement. This condition exposed employees to a struck-by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 P.S.I.:  Buskin River Road, Maintenance Shop: On or about 30 July 2019, an air nozzle did not have a 30 P.S.I reducing device. This condition exposed employees to air embolism/laceration hazards if dead-ended against their skin.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View FISH AND WILDLIFE SERVICE's full OSHA safety record →