Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ALVAREZ INDUSTRIES LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of ALVAREZ INDUSTRIES LLC in 312 BOSTON POST ROAD, ORANGE, CT 06477 (NAICS 332312). OSHA activity number 343976809.

Watch Alvarez Industries LLC — free Get an email when a new federal OSHA severe-injury report for Alvarez Industries LLC is published. One employer, no account, unsubscribe in one click.
Site address
312 BOSTON POST ROAD
City
ORANGE
State
CT
ZIP
06477
Mailing
312 BOSTON POST ROAD, ORANGE, CT 06477
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
8
Ownership type
A

16 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $1875.00 · Current $1150.00 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition:    Facility:  The walking-working surfaces were not kept clean and orderly where the items listed below, but not limited to, cluttered the walk ways exposing employees to trips, slips, and fall hazards:                1.  The wood blocks that extended into the walking aisle.              2.  The metal conduit was causing a tripping hazard.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $1875

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $3751.00 · Current $2250.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Shearer Machine Area:  The crushing points, created by the "Drop Arms" of the Shearer machine were not guarded.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3751

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  Automatic Bending Machine Area:  The point of operation of the Automatic Bending machine was not guarded..
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.145 C02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1875.00 · Current $1150.00 Reduced
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices:    Shearer Machine Area: Caution signs were not used to warn against potential hazards or to caution against unsafe practices while the shearer machine was in use.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $1875

1910.147 C01

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $2500.00 · Current $1500.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    Facility: The employer did not establish and implement a site specific hazardous energy control lockout/tagout program consisting of machine specific step-by-step written energy control procedures, employee training and periodic inspections for the employees during servicing and maintenance of equipment, such as (but not limited to) the shearer and automatic bending machines.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2500

1910.147 C04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(I): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    Facility: The employer did not establish and implement step-by-step hazardous energy control lockout/tagout procedures in the machine specific, including alternative measures for the employees during servicing and maintenance of equipment, such as (but not limited to) the shearer and automatic bending machines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:    Facility: The employees as "affected and/or other types" were not provided with training and information in the controlling of potential hazardous and unexpected release of energy sources during servicing and maintenance of equipment, such as (but not limited to) the shearer and automatic bending machines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.184 D

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $2500.00 · Current $1500.00 Reduced
29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not being inspected for damage or defects by a competent person designated by the employer:    Facility:  The slings including the fastenings and attachments were not being inspection daily before each use for damage or defects by a competent person.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2500

1910.184 F05 III

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.184(f)(5)(iii): Wire rope sling(s) that had kinking, crushing, bird caging or other damage resulting in distortion of the wire rope structure were not immediately removed from service:  Facility:  The wire rope slings that had bird caging were not immediately removed from service.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1875.00 · Current $1150.00 Reduced
29 CFR 1910.305(g)(1)(i): Flexible cords and cables were not approved for conditions of use and location:    Facility: The orange flexible extension cord used to power a lamp was running along the floor and exposed to sharp edges.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $1875

1904.32 A04

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1000.00 · Current $600.00 Reduced
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30:    Facility:  On April 2, 2019, the employer did not post the OSHA 300A Form or equivalent for the year of 2018 by February 1 thru April 30, 2019.
Recent events (2)
  • — I (O) $600
  • — Z (O) $1000

1910.25 B03

Other-than-serious 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $351.00 · Current $200.00 Reduced
29 CFR 1910.25(b)(3): The employer did not ensure that stairs have uniform riser heights and tread depths between landings:    Outside Storage Trailer:  The stairs to the trailer did not have uniform riser height and tread depths between landings.
Recent events (2)
  • — I (O) $200
  • — Z (O) $351

1910.37 A03

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  Bay 2 Area: The exit route of the exit door near Bay 2 was blocked by a flat bed truck parked in outside.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.38 B

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.38(b): The employer with less than 10 employees did not have an emergency action plan, either written or oral, with procedures for employees to follow in case of a fire or other emergency:  Facility:  The employer did not have an emergency action plan in place which included procedures for employees to follow in case of a fire or other emergency.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  Facility:  Portable fire extinguishers were not mounted and readily accessible.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 F01 IV

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:    Bending Table 2 Area: The Square D 480V circuit breaker box having built-in overcurrent devices was not readily accessible to employees.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ALVAREZ INDUSTRIES LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343976809.