Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CHRIS KIM ROOFING AND SIDING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CHRIS KIM ROOFING AND SIDING in 2137 EAST HUNTINGTON STREET, PHILADELPHIA, PA 19125 (NAICS 238160). OSHA activity number 343980140.

Watch Chris KIM Roofing AND Siding — free Get an email when a new federal OSHA severe-injury report for Chris KIM Roofing AND Siding is published. One employer, no account, unsubscribe in one click.
Site address
2137 EAST HUNTINGTON STREET
City
PHILADELPHIA
State
PA
ZIP
19125
Mailing
3023 GREENRIDGE DR., EAGLEVILLE, PA 19403
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.252 A

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2842.00 · Current $2842.00
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s):  a) Jobsite located at 2137 E Huntington Street, Philadelphia, PA: Employees were exposed to struck-by hazards while materials were dumped approximately 35 feet from a commercial roof to a dumpster on the ground without using safe means such as a chute.  Condition was observed on or about 2 MAY 2019.
Recent events (1)
  • — Z (S) $2842

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:  a) Jobsite located at 2137 E Huntington Street, Philadelphia, PA: Employees working on top of a commercial roof were not provided adequate fall protection; thus exposing employees of falls of approximately 35 feet.  Condition was observed on or about 2 MAY 2019.
Recent events (1)
  • — Z (S) $3978

1926.503 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) Jobsite located at 2137 E Huntington Street, Philadelphia, PA: Employees working on top of a commercial roof were not provided adequate fall protection training; thus exposing employees of falls of approximately 35 feet.  Condition was observed on or about 2 MAY 2019.
Recent events (1)
  • — Z (S) $0

View CHRIS KIM ROOFING AND SIDING's full OSHA safety record →