Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EMPIRE BUILDERS OF CNY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EMPIRE BUILDERS OF CNY in 1603 WEST GENESEE STREET, SYRACUSE, NY 13204 (NAICS 236118). OSHA activity number 343993069.

Watch Empire Builders OF CNY — free Get an email when a new federal OSHA severe-injury report for Empire Builders OF CNY is published. One employer, no account, unsubscribe in one click.
Site address
1603 WEST GENESEE STREET
City
SYRACUSE
State
NY
ZIP
13204
Mailing
1419 COUNTY ROUTE 57, FULTON, NY 13069
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236118
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee was using eye protection when exposed to eye or face hazards from flying particles:    a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19:  One employee was cutting wood trim while using a compound miter saw, without eye protection.     a) 1603 West Genesee Street, northeast corner of building, on or about 5-7-19:  One employee was fastening wood trim with the use of a pneumatic nailer, without eye protection.
Recent events (3)
  • — C (S) $2273
  • — R (S) $2273
  • — Z (S) $2273

1926.304 F

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $2842.00
29 CFR 1926.304(f)  Section 4.1.2(b)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator:       29 CFR 1926.304(f)  Section 4.1.2(c)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:       29 CFR 1926.304(f)  Section 5.1.3.3  American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure:     a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19:  One employee was ripping wood trim using a table saw that was not equipped with a spreader.     b) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19:  One employee was ripping wood trim using a table saw that was not equipped with non kick-back fingers or "dogs".     c) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19:  One employee was ripping wood trim using a table saw that was not equipped with a magnetic switch or anti-restart device.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (3)
  • — C (S) $2842
  • — R (S) $2842
  • — Z (S) $2842

1926.304 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut:    a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19:  One employee was ripping wood trim using a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (3)
  • — C (S) $0
  • — R (S) $0
  • — Z (S) $0

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $2842.00
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:   a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19:  One employee was operating power tools (miter saw, table saw), powered through an extension cord and receptacle that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (3)
  • — C (S) $2842
  • — R (S) $2842
  • — Z (S) $2842

1926.405 G02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $2842.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19:  One employee was operating power tools (miter saw, table saw), powered through an extension cord that exhibited a broken strain relief.
Recent events (3)
  • — C (S) $2842
  • — R (S) $2842
  • — Z (S) $2842

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $2842.00
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:    a) 1603 West Genesee Street, northeast corner of building, on or about 5-7-19:  One employee was working while in an articulating, extensible boom, aerial lift, without a safety harness or body belt, exposing the employee to a fall hazard of 15 feet 6 inches.
Recent events (3)
  • — C (S) $2842
  • — F (S) $2842
  • — Z (S) $2842

CDC LLC