Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NTW LLC DBA NATIONAL TIRE & BATTERY #560 in 201 CAMBRIDGE STREET, ALLSTON, MA 02134 (NAICS 453998). OSHA activity number 344139779.

Watch NTW LLC DBA National Tire & Battery #560 — free Get an email when a new federal OSHA severe-injury report for NTW LLC DBA National Tire & Battery #560 is published. One employer, no account, unsubscribe in one click.
Site address
201 CAMBRIDGE STREET
City
ALLSTON
State
MA
ZIP
02134
Mailing
SAFETY DEPARTMENT - ATTN: CARMEN TORBUS 4280 PROFESSIONAL CENTER DRIVE, PALM BEACH GARDENS, FL 33410
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
Employees
6
Ownership type
A

4 citations on file for this inspection.

1910.252 A02 XIII C

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $9472.00 · Current $9472.00
29 CFR 1910.252(a)(2)(xiii)(C): The employer did not recognize its responsibility for the safe usage of cutting or welding equipment, and did not insist that cutters or welders and their supervisors were suitably trained in the safe operation of their equipment.  Location:  Facility  Employees using oxy-acetylene cutting equipment were not trained on its safe us.  .
Recent events (1)
  • — Z (S) $9472

1910.253 B02 IV

Serious Gravity 5 3 instances 6 exposed
Issued
Penalty
Initial $9472.00 · Current $9472.00
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  Location:  near center of Service Shop  Unused oxygen and acetylene cylinders were not capped.
Recent events (1)
  • — Z (S) $9472

1910.253 B04 I

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $9472.00 · Current $9472.00
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire;   Location:  Near Center of Service Room  An unused oxygen cylinder was stored adjacent to acetylene cylinders and hydraulic jack oil.
Recent events (1)
  • — Z (S) $9472

1910.253 E01

Serious Gravity 10 1 instance 6 exposed
Issued
Penalty
Initial $13260.00 · Current $13260.00
29 CFR 1910.253(e)(1): Equipment was not installed and used only in the service for which it was approved and as recommended by the manufacturer:  Location:  center of Service Area, acetylene cylinder on cart.  An acetylene regulator was badly damaged.