DALLAS, TX —
OSHA Inspection: BIG D CONCRETE INC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of BIG D CONCRETE INC in 10361 BICKHAM RD, DALLAS, TX 75220 (NAICS 327320). OSHA activity number 344170584.
Where did this inspection happen?
- Establishment
- BIG D CONCRETE INC
- Site address
- 10361 BICKHAM RD
- City
- DALLAS
- State
- TX
- ZIP
- 75220
- Mailing
- 10361 BICKHAM RD, DALLAS, TX 75220
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327320
- Employees
- 90
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.95 G06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels: (a) At the ready-mix plant, an employee who performed maintenance activities and was exposed to noise above an 8-hour time-weighted average of 85 decibels had not received an annual audiogram. The employee received a baseline audiogram on June 6, 2018.
Recent events (1)
- — Z (O) $0
1910.95 K02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.95(k)(2): The training program was not repeated annually for each employee included in the hearing conservation program: (a) At the ready-mix plant, an employee who performed maintenance activities was exposed to noise above an 8-hour time-weighted average of 85 decibels and the employer's training program was not repeated annually, including training on the following: the effects of noise on hearing; the purpose of hearing protectors, the advantages, disadvantages, and attenuation of various types, and instructions on selection, fitting, use, and care; and the purpose of audiometric testing, and an explanation of the test procedures.
Recent events (1)
- — Z (O) $0
More inspections at BIG D CONCRETE INC
DALLAS, TX—2021-10-21 00:00:00
BIG D CONCRETE, INC.
DALLAS, TX—2019-11-21 00:00:00
BIG D CONCRETE, INC.
DALLAS, TX—2017-10-24 00:00:00
BIG D CONCRETE INC
DALLAS, TX—2017-10-24 00:00:00
BIG D CONCRETE INC
View BIG D CONCRETE INC's full OSHA safety record →
More inspections in this industry (NAICS 327320)
SYRACUSE, NY—2026-07-17 00:00:00
CRANESVILLE BLOCK CO., INC.
LYNDEN, WA—2026-07-16 00:00:00
WA317992100 - STREMLER CONCRETE VOLUMETRIC MIXING LLC
RENO, NV—2026-07-09 00:00:00
R&K READY MIXED CONCRETE, LLC
RENO, NV—2026-07-09 00:00:00
R&K READY MIXED CONCRETE, LLC
MOUNT VERNON, IL—2026-07-08 00:00:00
BEELMAN READY-MIX INC
More inspections in TX
RICHMOND, TX—2026-07-17 00:00:00
CORNELIUS NURSERIES, INC.
HOUSTON, TX—2026-07-17 00:00:00
HOLLOWAY HOUSTON, INC.
BONHAM, TX—2026-07-17 00:00:00
VOLUNTARY PURCHASING GROUPS, INC.
SNYDER, TX—2026-07-16 00:00:00
RNWBL
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
Source