MEDWAY, MA —
OSHA Inspection: EXELON GENERATION COMPANY, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of EXELON GENERATION COMPANY, LLC in 9 SUMMER STREET, MEDWAY, MA 02053 (NAICS 237130). OSHA activity number 344236575.
Where did this inspection happen?
- Establishment
- EXELON GENERATION COMPANY, LLC
- Site address
- 9 SUMMER STREET
- City
- MEDWAY
- State
- MA
- ZIP
- 02053
- Mailing
- 300 EXELON WAY, KENNETT SQUARE, PA 19348
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 109
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C07 I B
- Issued
- Abate by
- Penalty
- Initial $13127.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure. Location: Worksite Employees were exposed to hazardous energy while working on a glycol system component where they has not been properly instructed in the manufactures energy control procedure. Actual Injury: On or about August 13 2019, employees were injured by flying debris when a rubber bladder exploded out of a pressurized vessel while preforming maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $13127
1910.147 D06
- Issued
- Abate by
- Penalty
- Initial $13127.00 · Current $9000.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished. Location: Worksite On or about August 13, 2019, employees were exposed to hazardous energy in the form of pressurized nitrogen while working on a glycol expansion tank that was not in normal operating condition due to failure of the bladder and was believed, erroneously, to be in a state of minimal or no hazardous pressure.
Recent events (2)
- — I (S) $9000
- — Z (S) $13127
More inspections at EXELON GENERATION COMPANY, LLC
LUSBY, MD—2019-12-06 00:00:00
EXELON GENERATION COMPANY, LLC
MARSEILLES, IL—2019-11-12 00:00:00
EXELON GENERATION COMPANY, LLC
LUSBY, MD—2018-03-08 00:00:00
EXELON GENERATION COMPANY, LLC
MORRIS, IL—2018-01-30 00:00:00
EXELON GENERATION COMPANY, LLC
LUSBY, MD—2016-03-03 00:00:00
EXELON GENERATION COMPANY, LLC
View EXELON GENERATION COMPANY, LLC's full OSHA safety record →
More inspections in this industry (NAICS 237130)
LEXINGTON, KY—2026-07-09
69310 - DAVIS H ELLIOT COMPANY INC
POUGHQUAG, NY—2026-07-09
MK SHARP LLC.
KENMORE, WA—2026-07-08
WA317991980 - CASCADE TOWER & RIGGING INC
HUBBARD, TX—2026-07-07
3B DOZER SERVICE LLC
ALBANY, OR—2026-07-06
317744661 - TEXSTAR ENTERPRISES LLC
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344236575.