BIRMINGHAM, AL —
OSHA Inspection: HUDSON COMPANY OF TENNESSEE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HUDSON COMPANY OF TENNESSEE in 1731 MONTGOMERY HWY, BIRMINGHAM, AL 35244 (NAICS 236220). OSHA activity number 344292248.
Where did this inspection happen?
- Establishment
- HUDSON COMPANY OF TENNESSEE
- Site address
- 1731 MONTGOMERY HWY
- City
- BIRMINGHAM
- State
- AL
- ZIP
- 35244
- Mailing
- PO BOX 429, HENAGAR, AL 35978
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 85
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.403 B02
- Issued
- Penalty
- Initial $6564.00 · Current $3938.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) On or about 9/06/19 - 1731 Montgomery Highway, Hoover, AL, a subcontractor was allowed to operate a Rigid Power Drive that was plugged into a receptacle housed in a metal box that was not mounted.
Recent events (2)
- — I (S) $3938.4
- — Z (S) $6564
1926.404 B01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: (a) On or about 9/06/19 - 1731 Montgomery Highway, Hoover, AL, a subcontractor was allowed to operate a Rigid Power Drive that was plugged into a receptacle that did not have a GFCI receptacle.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 A02 II I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points: (a) On or about 9/06/19 - 1731 Montgomery Highway, Hoover, AL, a subcontractor was allowed to operate a Rigid Power Drive plugged into an extension cord that was pinched under a metal door and connected to a receptacle inside the building.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at HUDSON COMPANY OF TENNESSEE
LAMBSBURG, VA—2021-03-10 00:00:00
HUDSON COMPANY OF TENNESSEE
ABINGDON, VA—2019-10-08 00:00:00
HUDSON COMPANY OF TENNESSEE
ANNISTON, AL—2019-04-02 00:00:00
HUDSON COMPANY OF TENNESSEE
JACKSON, TN—2017-10-16 00:00:00
HUDSON COMPANY OF TENNESSEE
BIRMINGHAM, AL—2016-09-30 00:00:00
HUDSON COMPANY OF TENNESSEE
View HUDSON COMPANY OF TENNESSEE's full OSHA safety record →
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in AL
CLANTON, AL—2026-07-13
UBIQUE TECHNOLOGIES, INC.
IRONDALE, AL—2026-07-13
FATHER NATURE LANDSCAPES OF BIRMINGHAM, INC.
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
CULLMAN, AL—2026-07-09
ALFREDO PICHARDO BLANCO
MOBILE, AL—2026-07-09
FLEXICREW TECHNICAL, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344292248.