WOBURN, MA —
OSHA Inspection: DUFFY BROS. MANAGEMENT COMPANY, INC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of DUFFY BROS. MANAGEMENT COMPANY, INC in 285 LOCUST ST., WOBURN, MA 01801 (NAICS 236116). OSHA activity number 344381405.
Where did this inspection happen?
- Establishment
- DUFFY BROS. MANAGEMENT COMPANY, INC
- Site address
- 285 LOCUST ST.
- City
- WOBURN
- State
- MA
- ZIP
- 01801
- Mailing
- 465 WAVERLY OAKS ROAD SUITE 500, WALTHAM, MA 02452
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 32
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.178 L
- Issued
- Penalty
- Initial $10210.00 · Current $4000.00 Reduced
General-duty citation text
29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks: 285 Locust St., Woburn, MA On or about October 16, 2019, an employee operating a Lull Powered Industrial Truck was not trained or evaluated in the safe operation of the equipment.
Recent events (3)
- — F (S) $4000
- — C (S) $10210
- — Z (S) $10210
1926.20 B02
- Issued
- Abate by
- Penalty
- Initial $10210.00 · Current $4000.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program that provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person. Location: Building 7, 225 Locust St., Woburn, MA On or about October 16, 2019, the employer's competent person did not conduct adequate frequent and regular inspections of the jobsite to identify the lack of: fire extinguishing equipment; energized electrical cord defects; lack of stair rails/handrails on stairways; non-uniformed stair riser heights; untrained and non-evaluated powered industrial truck operators; inadequate use of fall protective equipment; and the use of automotive tow straps as rigging slings.
Recent events (3)
- — F (S) $4000
- — C (S) $10210
- — Z (S) $10210
1926.24
- Issued
- Penalty
- Initial $7293.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.24: The employer shall be responsible for the development and maintenance of an effective fire protection and prevention program at the job site throughout all phases of the construction, repair, alteration, or demolition work. The employer shall ensure the availability of the fire protection and suppression equipment required by Subpart F of this part. Building 7, 285 Locust St., Woburn, MA The employer failed to provide fire-extinguishing equipment for type A, B or C fires during the construction of a wood frame residential building, storage areas of 5-gallon gasoline cans and gasoline powered equipment, and energized electrical cords and tool operations.
Recent events (3)
- — F (O) $2000
- — C (S) $7293
- — Z (S) $7293
1926.251 A01
- Issued
- Abate by
- Penalty
- Initial $7293.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.251(a)(1): Rigging equipment for material handling was not inspected prior to use on each shift and as necessary during its use to ensure that it was safe: Building7, 285 Locust St., Woburn, MA On or about October 16, 2019, workers were exposed to falling suspended loads being hoisted by the forks of a powered industrial truck with an automotive tow strap that was not designed, proof-tested prior to use to 125 percent of their rated load. The rated capacities by sling configuration (i.e., working load limits) were not indicated on the sling by permanently affixed and legible identification markings prescribed by the manufacturer.
Recent events (3)
- — F (O) $2000
- — C (S) $7293
- — Z (S) $7293
1926.1052 A03
- Issued
- Abate by
- Penalty
- Initial $7293.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1052(a)(3): Variations in riser height or tread depth were over 1/4-inch (0.6 cm) in any stairway system: Building 7, 285 Locust St., Woburn, MA On or about October 16, 2019, employees were exposed to falling hazards while ascending and descending an exterior stairway with four or more risers that did not have uniform riser height.
Recent events (3)
- — F (O) $1000
- — C (S) $7293
- — Z (S) $7293
1926.1052 C01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stair rail system along each unprotected side or edge: Building 7, 285 Locust St., Woburn, MA On or about October 16, 2019, employees were exposed to falling hazards while ascending and descending stairways with four or more risers that did not have at least one handrail and one stairrail system along each unprotected side or edge Building number 7: 1. Three stairways leading to the basement 2. Three stairways leading to the interior from the exterior.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1926.404 F06
- Issued
- Abate by
- Penalty
- Initial $10210.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Building 7, 285 Locust St., Woburn, MA On or about October 16 2019, employees were exposed to electrical shock hazards from a damage/defective extension cord that had the ground pin broken away from the plug end. exposing the live conductor wires.
Recent events (3)
- — F (O) $1000
- — C (S) $10210
- — Z (S) $10210
1926.405 G02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: Building 7, 225 Locust St., Woburn, MA On or about October 16, 2019, employees were exposed to shock hazards from tools and cords where the outer casing had pulled way from the plug end exposing the energized conductor wires.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.416 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: Building 7, 225 Locust St., Woburn, MA On or about October 16, 2019, employees were exposed to shock hazards from tools and multiple extension cords where the outer casing was damage/defective exposing the energized conductor wires.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236116)
PLAIN CITY, OH—2026-07-09
RUSCILLI CONSTRUCTION
IRVINE, CA—2026-07-09
TOLL BROTHERS INC.
ROSEVILLE, CA—2026-07-09
JERRY LEE STAIRS INC.
NEWPORT, RI—2026-07-08
PEZZUCO CONSTRUCTION INC.
EVANSVILLE, IN—2026-07-08
L & J CONSTRUCTORS, LLC
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344381405.