On , OSHA opened a follow-up health inspection of U.S. BATTERY MFG. AUGUSTA, INC. in 1895 TOBACCO RD, AUGUSTA, GA 30906 (NAICS 335912). OSHA activity number 344415807.

Watch U.S. Battery MFG. Augusta, INC. — free Get an email when a new federal OSHA severe-injury report for U.S. Battery MFG. Augusta, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1895 TOBACCO RD
City
AUGUSTA
State
GA
ZIP
30906
Mailing
1895 TOBACCO RD, AUGUSTA, GA 30906
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335912
Employees
234
Ownership type
A

3 citations on file for this inspection.

1910.134 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $8856.00 · Current $4426.00 Reduced

Hazardous substances 1591

29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:    a) U.S. Battery Mfg. Augusta, Inc. - In the Oxide plant, an employee was provided and required to use a full face negative pressure respirator for protection against lead exposure. An annual fit test for the full face was not performed, on or about 10/30/19.    b) U.S. Battery Mfg. Augusta, Inc. - In the Oxide plant, an employee was provided and required to use a half mask negative pressure respirator for protection against lead exposure. The last fit test was performed on 8/28/18 and not repeated within 12 months, on or about 10/30/19.
Recent events (2)
  • — I (S) $4426
  • — Z (S) $8856

1910.1025 H01

Repeat Gravity 5 2 instances 5 exposed
Issued
Penalty
Initial $52096.00 · Current $26048.00 Reduced

Hazardous substances 1591

29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:    a) U.S. Battery Mfg. Augusta, Inc. - At the Oxide plant break room, employees were exposed to ingestion hazards from lead contamination found on the refrigerator handle. Lead contamination measured was 272.7 micrograms, on or about 10/31/19.    b) U.S. Battery Mfg. Augusta, Inc. - At the Oxide plant break room, employees were exposed to ingestion hazards from lead contamination found on the microwave control pad. Lead contamination measured was 14.5 micrograms, on or about 10/31/19.    U.S. Battery Mfg. Augusta, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1025(h)(1), which was contained in OSHA inspection number 1353892, citation number 1, item number 7 and was affirmed as a final order on 3/15/19, with respect to a workplace located at 1895 Tobacco Rd, Augusta, GA.
Recent events (2)
  • — I (R) $26048
  • — Z (R) $52096

1904.29 B02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1772.00 · Current $886.00 Reduced
29 CFR 1904.29(b)(2): The employer did not fill out or correctly fill out an OSHA Form 301 or equivalent for each recordable injury or illness.    U.S. Battery Mfg. Augusta, Inc. - In the Oxide plant, an employee was removed from the site due to a blood lead level above 60 ug/dL. An incident report OSHA 301 or equivalent form was not completed. The information documented did not state what the employee was doing before the exposure that caused the increased of lead in blood and how the incident occurred, on or about 10/30/19.
Recent events (2)
  • — I (O) $886
  • — Z (O) $1772

View U.S. BATTERY MFG. AUGUSTA, INC.'s full OSHA safety record →