WELLINGTON, OH —
OSHA Inspection: FOREST CITY TECHNOLOGIES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FOREST CITY TECHNOLOGIES, INC. in 401 MAGYAR STREET, WELLINGTON, OH 44090 (NAICS 336390). OSHA activity number 344488135.
Where did this inspection happen?
- Establishment
- FOREST CITY TECHNOLOGIES, INC.
- Site address
- 401 MAGYAR STREET
- City
- WELLINGTON
- State
- OH
- ZIP
- 44090
- Mailing
- 299 CLAY STREET P.O. BOX 86, WELLINGTON, OH 44090
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336390
- Employees
- 58
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $9012.00 · Current $9012.00
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Forest City Technologies, Inc. located at 401 Magyar Street in Wellington, Ohio; On or about December 4, 2019 the employer did not ensure employees were protected while operating the DC-12, IC-2, and BC-3 FTS Coating Machines. Employees were exposed to caught in hazards in that the rotating index wheels are not guarded.
Recent events (1)
- — Z (S) $9012
1910.147 C06 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Forest City Technologies, Inc. located at 401 Magyar Street in Wellington, Ohio; On or about December 4, 2019 the employer did not ensure periodic audits of energy control procedures were completed at least annually. Set-Up employees and maintenance personnel are required to perform change overs and set-up activities on coating machines such as, but not limited to, P-14, A&C-6, and IC-1, which require energy control procedures that have not been reviewed for deficiencies.
Recent events (1)
- — Z (O) $0
More inspections at FOREST CITY TECHNOLOGIES, INC.
WELLINGTON, OH—2019-01-25 00:00:00
FOREST CITY TECHNOLOGIES, INC.
WELLINGTON, OH—2016-08-08 00:00:00
FOREST CITY TECHNOLOGIES, INC.
WELLINGTON, OH—2006-11-16 00:00:00
FOREST CITY TECHNOLOGIES INC.
CLEVELAND, OH—2003-06-12 00:00:00
FOREST CITY TECHNOLOGIES INC.
CLEVELAND, OH—2001-04-25 00:00:00
FOREST CITY TECHNOLOGIES INC.
View FOREST CITY TECHNOLOGIES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336390)
CIRCLEVILLE, OH—2026-07-07
ENGINEERED PLASTIC COMPONENTS INC.
BENTON HARBOR, MI—2026-06-30
LINAMAR STRUCTURES GROUP
NEW HUDSON, MI—2026-06-30
COSMA BODY ASSEMBLY MICHIGAN
OGDEN, UT—2026-06-23
AUTOLIV ASP INC
EL PASO, TX—2026-05-28
HANON SYSTEMS LLC (CLIMATE)
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source