Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: CONTAINER MAINTENANCE CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CONTAINER MAINTENANCE CORPORATION in 100 INTERNATIONAL COMMERCE BOULEVARD, GREER, SC 29651 (NAICS 488390). OSHA activity number 344507660.

Watch Container Maintenance Corporation — free Get an email when a new federal OSHA severe-injury report for Container Maintenance Corporation is published. One employer, no account, unsubscribe in one click.
Site address
100 INTERNATIONAL COMMERCE BOULEVARD
City
GREER
State
SC
ZIP
29651
Mailing
2265 CLEMENTS FERRY ROAD SUITE 301, CHARLESTON, SC 29492
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488390
Employees
18
Ownership type
A

3 citations on file for this inspection.

1910.303 B02

Serious Gravity 1 1 instance 18 exposed
Issued
Penalty
Initial $5407.00 · Current $3244.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) East Wall of the Office Trailer: A relocatable power tap designed and listed to provide power to high concentrations of low powered loads such as computers, TV's, stereos, printers, etc. was used to provide power to high powered loads such as a  Frigidaire full sized refrigerator; a Primo water dispenser and ice maker; and a Wal-Mart microwave oven.
Recent events (2)
  • — I (S) $3244.2
  • — Z (S) $5407

1910.304 B02

Serious Gravity 1 1 instance 18 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served:  a) East Wall of the Office Trailer: A relocatable power tap was used to provide power to a Frigidaire full sized refrigerator (6 amps); a Primo water dispenser and ice maker (6 amps); and a Wal-Mart microwave oven (12.5 amps), with a total of 24.5 amps, which is 9.5  more than the power taps 15 amp capacity.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1917.152 D01 XVI

Serious Gravity 1 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $5407.00 · Current $3244.00 Reduced
29 CFR 1917.152(d)(1)(xvi): Oxygen cylinders were not separated from fuel gas cylinders and combustible materials by either a minimum distance of 20 feet (6.1 m) or a barrier having a fire-resistance rating of 30 minutes.  a) Worksite: oxygen and acetylene compressed gas cylinders in the back of utility trucks used at the site were found to have been left on the truck and not used on the weekends or during holidays. They should have been placed in storage where they are separated by a distance 20 feet from each other, or had a fire resistant barrier between them.  b) North end of the Car Port Bay: An oxygen and LP Gas compressed gas cylinders were used on an intermittent basis by employees to perform cutting jobs were left together on a welding cart over weekends and holidays,  were not removed from the welding cart and placed in storage where they are separated by a distance 20 feet from each other, or had a fire resistant barrier between them.   ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $3244.2
  • — Z (S) $5407

View CONTAINER MAINTENANCE CORPORATION's full OSHA safety record →