2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ENGINEERED BONDING SOLUTIONS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ENGINEERED BONDING SOLUTIONS, LLC in 801 MARINA RD., TITUSVILLE, FL 32796 (NAICS 325520). OSHA activity number 344581483.

Watch Engineered Bonding Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Engineered Bonding Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
801 MARINA RD.
City
TITUSVILLE
State
FL
ZIP
32796
Mailing
801 MARINA RD., TITUSVILLE, FL 32796
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325520
Employees
17
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $5398.00 · Current $3239.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:  a.  On or about January 24, 2020, in the warehouse area, the employer did not ensure the two tier industrial storage racks were properly anchored to the floor.   b.  On or about January 24, 2020, in the warehouse area, the two tier industrial storage racks were overloaded, per the posted rated load.
Recent events (2)
  • — I (S) $3238.8
  • — Z (S) $5398

1910.28 B01 I C

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3856.00 · Current $2314.00 Reduced
29 CFR 1910.28(b)(1)(i)(C): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by a personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems:  a. On or about January 24, 2020, the platform around an above ground storage tank was not guarded on all sides and employees were not protected from falling 11 feet 5 inches, from the platform to the ground below.
Recent events (2)
  • — I (S) $2313.6
  • — Z (S) $3856

1910.38 B

Other-than-serious 1 instance 17 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review:  a.  On or about January 24, 2020, the employer did not have a written emergency action plan onsite for employees to review.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.176 C

Other-than-serious 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.176(c): Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage:  a.  On or about January 24, 2020, in the warehouse area, plastic barrels and cardboard boxes were blocking the walkway used by employees, thus creating a tripping hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a.  On or about January 24, 2020, in the warehouse area, extension cords were being used as permanent wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a.  On or about January 24, 2020, in the warehouse area, the extension cord used to supply power to a floor scale did not have a strain relief connecting the cord to the plug and the insulated wires inside the cord were visible.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ENGINEERED BONDING SOLUTIONS, LLC's full OSHA safety record →