ENGLEWOOD, CO —
OSHA Inspection: KUMPF LINCOLN MERCURY
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of KUMPF LINCOLN MERCURY in 5000 S BROADWAY, ENGLEWOOD, CO 80113 (NAICS 811111). OSHA activity number 344646773.
Where did this inspection happen?
- Establishment
- KUMPF LINCOLN MERCURY
- Site address
- 5000 S BROADWAY
- City
- ENGLEWOOD
- State
- CO
- ZIP
- 80113
- Mailing
- 5000 S BROADWAY, ENGLEWOOD, CO 80113
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 68
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.134 D03 III B 2
- Issued
- Abate by
- Penalty
- Initial $4048.00 · Current $2400.00 Reduced
General-duty citation text
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an ESLI that would ensure cartridges were changed before the end of their service life: (a) On or about February 21, 2020, and at times prior, the employer did not protect employees that used half-face tight fitting air purifying respirators, while conducting paint prep operations and painting operations, by developing and implementing a cartridge change schedule to prevent breakthrough of the organic vapor cartridges used with the respirators. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2400
- — Z (S) $4048
1910.134 E01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On or about February 21, 2020, and at times prior, paint department employees wore half-face tight fitting air purifying respirators without first being medically evaluated to ensure that they were physically fit to wear the respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter: (a) On or about February 21, 2020 and at times prior, employees were exposed to respiratory hazards when engaging in prepping, painting and finish operations while using half-face tight fitting respirators without first being fit tested.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 G01 I A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a) On or about February 21, 2020, and at times prior, employees of the paint and collision department were exposed to were exposed to unknown concentrations of particulates because of facial hair which potentially interfered with the seal of the half face tight fitting respirators they used. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a) On or about February 21, 2020, and at times prior, the employer did not provide employee(s) with Appendix D of the respirator standard, which contains information for voluntary use, where employees were voluntarily using N95 particulate-filtering facepiece respirators. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $4048.00 · Current $2400.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) On or about February 21, 2020, and at times prior, the employer exposed employees to stuck-by hazards due to the Baldor bench grinder work rest, located in the service area, not being adjusted to one eighth inch. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2400
- — Z (S) $4048
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) On February 21, 2020, and at times prior, the employer exposed employees in the service area to struck-by hazards due to bench grinder tongue guard exceeding one fourth inch. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E09 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: (a) On or about February 21, 2020, and at times prior, employees were exposed to fire hazards because trash from the paint mixing room was stored in an open plastic trash can instead of a closed metal receptacle. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about February 21, 2020, and at times prior, the employer did not maintain a clear distance of three feet in front of the circuit breaker panels and transformers in order to permit safe operation and maintenance of equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical. (a) On or about February 21, 2020, and at times prior, the employer, did not ensure employees were protected from chemical hazards. Numerous secondary containers, located in the detail and service department, were used for, but not limited to, wipe 'n shine, concentrated heavy duty cleaner (corrosive) and windshield washer fluid and did not have product identifiers on them to alert of hazards associated with each chemical. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811111)
SHERIDAN, CO—2026-07-15 00:00:00
JOHN'S COLLISION REPAIR, INC.
MANASSAS, VA—2026-07-15 00:00:00
VAFMC LLC
NORFOLK, VA—2026-07-15 00:00:00
CITY OF NORFOLK DEPT OF GENERAL SERVICES DIVISION OF FLEET MANAGEMENT
ENOLA, PA—2026-07-15 00:00:00
ENOLA AUTO SALES
LYNCHBURG, TN—2026-07-14 00:00:00
MOORE COUNTY SCHOOLS - BUS GARAGE
More inspections in CO
BROOMFIELD, CO—2026-07-16 00:00:00
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15 00:00:00
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15 00:00:00
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15 00:00:00
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15 00:00:00
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344646773.