PRATT, KS —
OSHA Inspection: PRATT ENERGY, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRATT ENERGY, LLC. in 10333 NE 30TH STREET, PRATT, KS 67124 (NAICS 325193). OSHA activity number 344704358.
Where did this inspection happen?
- Establishment
- PRATT ENERGY, LLC.
- Site address
- 10333 NE 30TH STREET
- City
- PRATT
- State
- KS
- ZIP
- 67124
- Mailing
- P O BOX 410, PRATT, KS 67124
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325193
- Employees
- 40
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C05 II D
- Issued
- Abate by
- Penalty
- Initial $4048.00 · Current $2834.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s): Employees engaged in servicing and maintenance activities throughout the entire plant were exposed to electrical, struck-by and caught-between hazards in that lockout devices and tagout devices did not indicate the identity of the employee applying the device, on the following equipment: a) EP-2302 Mash Cooler (A) Air by the Sump area of the Cook Building, b) Condensate Flush Line, and c) PM-8510 A box by the acid pump.
Recent events (2)
- — I (O) $2833.6
- — Z (S) $4048
1910.147 C06 II
- Issued
- Abate by
- Penalty
- Initial $4048.00 · Current $2834.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that the periodic inspections have been performed: Employees engaged in servicing, and maintenance activities throughout the entire plant at the following equipment but not limited to the Beer Mash Exchanger A Box #2, the PC-4113 Pre-Heater Plush Pump Box #12, the Paddle Pre-Mixer BP-5401, the mixer, the Acid pump, the blend enzyme tank pump, the Cook Tube Seal Box #14, and the Hammermill Box #22, which had multiple energy sources including pneumatic, electric, hydraulic, and gravity were exposed to electrical, struck-by and caught-between hazards in that periodic inspections of the energy control procedures for equipment were not performed.
Recent events (2)
- — I (O) $2833.6
- — Z (S) $4048
More inspections at PRATT ENERGY, LLC.
PRATT, KS—2019-07-15 00:00:00
PRATT ENERGY, LLC.
View PRATT ENERGY, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 325193)
GREENVILLE, OH—2026-06-25
THE ANDERSONS RENEWABLES LLC
FORT DODGE, IA—2026-06-23
A09CS000010FBESAAK - VALERO RENEWABLE FUELS COMANY, LLC
VAN NUYS, CA—2026-05-08
ANHEUSER-BUSCH, LLC
MADRID, NE—2026-04-29
MID AMERICA AGRI PRODUCTS
LIBERAL, KS—2026-03-23
CONESTOGA ENERGY PARTNERS, LLC.
More inspections in KS
WICHITA, KS—2026-07-10
DIVERSIFIED SERVICES, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
WICHITA, KS—2026-07-09
FIGEAC AERO NORTH AMERICA, INC.
PITTSBURG, KS—2026-07-08
CDL ELECTRIC
WICHITA, KS—2026-07-08
IBT, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344704358.