SPRINGFIELD, OH —
OSHA Inspection: MEVA FORMWORK SYSTEMS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MEVA FORMWORK SYSTEMS, INC. in 2000 AIRPARK DRIVE, SPRINGFIELD, OH 45502 (NAICS 332312). OSHA activity number 344891916.
Where did this inspection happen?
- Establishment
- MEVA FORMWORK SYSTEMS, INC.
- Site address
- 2000 AIRPARK DRIVE
- City
- SPRINGFIELD
- State
- OH
- ZIP
- 45502
- Mailing
- 2000 AIRPARK DRIVE, SPRINGFIELD, OH 45502
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 73
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.25 B03
- Issued
- Abate by
- Penalty
- Initial $3036.00 · Current $1670.00 Reduced
General-duty citation text
29 CFR 1910.25(b)(3): The employer must ensure: Stairs have uniform riser heights and tread depths between landings. a) On or about September 1, 2020, employees working at the small wash bay were required to access a platform that did not have uniform riser heights. The heights of the risers were 2 inches, 4 inches, and 7 inches.
Recent events (2)
- — I (S) $1669.8
- — Z (S) $3036
1910.28 B11 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.28(b)(11)(ii): The employer must ensure: Each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as follows: (see TABLE D-2) Stair width less than 44 inches with two open sides requires one stair rail system on each open side. a) On or about September 1, 2020, employees working at the small wash bay were required to access a platform that did not have handrails on the two open sides where there were 5 risers. b) On or about September 1, 2020, employees working at the big wash bay were required to access a platform that did not have handrails on one of the two open sides where there were 5 risers.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $3036.00 · Current $1670.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. a) On or about November 10, 2020, the employer had not required an energy control procedure to be utilized for isolating the powered conveyor at the big wash bay while employees stand on the panels placed on top of the conveyor and using a power scrubber.
Recent events (2)
- — I (S) $1669.8
- — Z (S) $3036
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. a) On or about November 10, 2020, the employer had not required the application of lockout and tagout devices to control and isolate energy (mechanical) when employees stand on the powered conveyor at the big wash bay while standing on the panels placed on top of the conveyor and using a power scrubber.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 J02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Hooks with deformation or cracks. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected. For hooks with cracks or having more than 15 percent in excess of normal throat opening or more than 10� twist from the plane of the unbent hook refer to paragraph (l)(3)(iii)(a) of this section. a) On or about November 10, 2020, the employer did not conduct a monthly certification of the hook inspections for the bay wash overhead crane for the Harrington 1 ton hoist SN00002653.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.179 J02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(j)(2)(iv): Hoist chains, including end connections, for excessive wear, twist, distorted links interfering with proper function, or stretch beyond manufacturer's recommendations. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected. a) On or about November 10, 2020, the employer did not conduct a monthly certification inspection of the chain hoist for the bay wash overhead crane for the Harrington 1 ton hoist SN00002653.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1)(i): A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas. a) On or about September 1, 2020, the employer did not provide a complete list of the hazardous chemicals known to be present in that chemicals such as but not limited to Jasco Acetone , Jasco Paint Thinner, O'Reilly Engine Degreaser, O'Reilly Brake Part Cleaner, and WD-40 Specialist Rust Remover Soak were not present on the list.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16 00:00:00
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16 00:00:00
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15 00:00:00
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14 00:00:00
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14 00:00:00
C & S CANOPY, INC.
More inspections in OH
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16 00:00:00
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15 00:00:00
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15 00:00:00
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15 00:00:00
KENWORTH
Source