Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: XGD SYSTEMS USA OPERATIONS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of XGD SYSTEMS USA OPERATIONS in 300 WELLESLEY AVENUE, WELLESLEY, MA 02481 (NAICS 238910). OSHA activity number 345008023.

Watch XGD Systems USA Operations — free Get an email when a new federal OSHA severe-injury report for XGD Systems USA Operations is published. One employer, no account, unsubscribe in one click.
Site address
300 WELLESLEY AVENUE
City
WELLESLEY
State
MA
ZIP
02481
Mailing
415 NORTHWEST FLAGLER AVENUE UNIT 302, STUART, FL 34994
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $5803.00 · Current $2000.00 Reduced
29 CFR  1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  Location:  Job site  Employees did not use hard hats despite being exposed to a struck-by hazard from airborne pieces of plywood.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $5803

1926.300 B02

Serious Gravity 10 1 instance 6 exposed
Issued
Penalty
Initial $9557.00 · Current $6000.00 Reduced
29 CFR  1926.300(b)(2):Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.  Location:  Job site  Instance A:  The employer did not prevent exposure to a rotating part on the recoil starter. Instance B:  The employer did not prevent exposure to unguarded belts and pulleys on the Ditch Witch trencher.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $9557

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345008023.