SYRACUSE, NY —
OSHA Inspection: NORTHSIDE COLLISION EASTWOOD LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of NORTHSIDE COLLISION EASTWOOD LLC in 3020 BURNET AVENUE, SYRACUSE, NY 13206 (NAICS 811121). OSHA activity number 345154520.
Where did this inspection happen?
- Establishment
- NORTHSIDE COLLISION EASTWOOD LLC
- Site address
- 3020 BURNET AVENUE
- City
- SYRACUSE
- State
- NY
- ZIP
- 13206
- Mailing
- 3020 BURNET AVENUE, SYRACUSE, NY 13206
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 9
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.106 E06 I
- Issued
- Penalty
- Initial $3946.00 · Current $2368.00 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken: a) Paint Mixing Room, on or about 2/19/2021: Employees adding flammable waste material to a 30 gallon container of flammable waste without grounding the 30 gallon container. b) Paint Mixing Room, on or about 2/19/2021: Employees dispensing from a 5 gallon container of DT-5 Virgin Lacquer Thinner a flammable material and the 5 gallon container was not grounded. c) Paint Mixing Room, on or about 2/19/2021: Employees dispensing from a 5 gallon container of Universal MID Temp Reducer a flammable material and the 5 gallon container was not grounded.
Recent events (2)
- — I (S) $2367.6
- — Z (S) $3946
1910.106 E06 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) Paint Mixing Room, on or about 2/19/2021: Employees adding flammable waste material to a 30 gallon container of flammable waste with no means of electrically interconnecting the nozzle and the portable container. b) Paint Mixing Room, on or about 2/19/2021: Employees dispensing from a 5 gallon container of DT-5 Virgin Lacquer Thinner a flammable material and the 5 gallon container with no means of electrically interconnecting the nozzle and the portable container. c) Paint Mixing Room, on or about 2/19/2021: Employees dispensing from a 5 gallon container of Universal MID Temp Reducer a flammable material and the 5 gallon container with no means of electrically interconnecting the nozzle and the portable container.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 811121)
MELROSE, MN—2026-07-16 00:00:00
111612 - GERBER COLLISION MIDWEST DBA GERBER COLLISION - GL
RIPON, WI—2026-07-15 00:00:00
SENECA FOODS CORPORATION
PORTLAND, OR—2026-07-13 00:00:00
317744734 - ATC AUTOBODY & PAINT LLC
SUMMIT, IL—2026-07-08 00:00:00
BUDS BODY SHOP SUPPLY & PAINT
PUYALLUP, WA—2026-07-08 00:00:00
WA317991990 - GLASS WORKS PRO INC
More inspections in NY
LIBERTY, NY—2026-07-17 00:00:00
SULLIVAN COUNTY CARE CENTER AT SUNSET LAKE
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
ONEONTA, NY—2026-07-17 00:00:00
APPLE CONVERTING, INC.
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
SYRACUSE, NY—2026-07-17 00:00:00
CRANESVILLE BLOCK CO., INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345154520.