MASSILLON, OH —
OSHA Inspection: TRADITIONAL ROOFING, LTD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRADITIONAL ROOFING, LTD in NEXT TO 9493 EMERALD ISLE ST NE, MASSILLON, OH 44646 (NAICS 238160). OSHA activity number 345204333.
Where did this inspection happen?
- Establishment
- TRADITIONAL ROOFING, LTD
- Site address
- NEXT TO 9493 EMERALD ISLE ST NE
- City
- MASSILLON
- State
- OH
- ZIP
- 44646
- Mailing
- 4003 OAK RIDGE RD NW, SUGARCREEK, OH 44681
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $4096.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. On or about March 16, 2021, during the installation of roofing material at a job site located at 9493 Emerald Isle St NW, Massillon, Ohio 44646; the employer did not ensure employees working on a roof of a single family home were protected from a fall of approximately 22.1 feet by utilizing a fall protection system.
Recent events (2)
- — I (S) $2250
- — Z (S) $4096
1926.1053 B01
- Issued
- Penalty
- Initial $4096.00 · Current $1350.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about March 16, 2021 at the job site located at 9493 Emerald Isle St NW, Massillon, Ohio 44646; during the installation of roofing material on a residential roof, the employer did not ensure portable ladders extended 3 feet above the upper landing surface.
Recent events (2)
- — I (S) $1350
- — Z (S) $4096
More inspections at TRADITIONAL ROOFING, LTD
ORRVILLE, OH—2025-07-15
TRADITIONAL ROOFING, LTD
View TRADITIONAL ROOFING, LTD's full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345204333.