CENTRAL SQUARE, NY —
OSHA Inspection: WRM REMODELING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WRM REMODELING LLC in LOT 48, WATER TOWER LANDING, WATER TOWER LANE, CENTRAL SQUARE, NY 13036 (NAICS 238130). OSHA activity number 345334361.
Where did this inspection happen?
- Establishment
- WRM REMODELING LLC
- Site address
- LOT 48, WATER TOWER LANDING, WATER TOWER LANE
- City
- CENTRAL SQUARE
- State
- NY
- ZIP
- 13036
- Mailing
- 8847 NY-5 ROAD EAST, MANLIUS, NY 13104
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.404 B01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection: a) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were using power tools that were energized with a Generac 5500 generator without GFI protection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.405 G02 IV
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iv):Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were connecting and disconnecting a Makita compressor where the cord to that compressor was pulled free from the tools housing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.416 E01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were connecting and disconnecting a Makita compressor where the cord to that compressor was pulled free from the tools housing, the cord was damaged, and the tape repair to the cord had pulled free.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1052 C01 II
- Issued
- Penalty
- Initial $3511.00 · Current $2633.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were using an interior stairway between the first and second floor where no hand rails were installed. b) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were using an interior stairway between the first and basement floor where no hand rails were installed.
Recent events (2)
- — I (S) $2633.25
- — Z (S) $3511
1926.1053 B04
- Issued
- Penalty
- Initial $1755.00 · Current $1316.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were using a 5 foot step ladder as a support for a pick and where that ladder was not open with the spreaders locked.
Recent events (2)
- — I (S) $1316.25
- — Z (S) $1755
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16 00:00:00
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16 00:00:00
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15 00:00:00
TRIPLE R CONSTRUCTION LLC
More inspections in NY
MAYVILLE, NY—2026-07-16 00:00:00
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16 00:00:00
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16 00:00:00
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15 00:00:00
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15 00:00:00
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345334361.