Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ROTOBEC USA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ROTOBEC USA, INC. in 162 ROTOBEC DR., LITTLETON, NH 03561 (NAICS 333923). OSHA activity number 345374680.

Watch Rotobec USA, INC. — free Get an email when a new federal OSHA severe-injury report for Rotobec USA, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ROTOBEC USA, INC.
Site address
162 ROTOBEC DR.
City
LITTLETON
State
NH
ZIP
03561
Mailing
162 ROTOBEC DR., LITTLETON, NH 03561
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333923
Employees
65
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 3 instances 50 exposed
Issued
Abate by
Penalty
Initial $12288.00 · Current $9216.00 Reduced

Hazardous substances E200

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to fire hazards due to deficient design and/or implementation of preventive and/or protective measures in its dust collection system:   Plasma Cutter Dust Collection System- The dust collection duct that carried combustible fine steel dust from the plasma cutter to the dust collector was not equipped with spark detection or fire suppression devices to prevent any sparks, embers or fires in the combustible steel dust from spreading to the dust collector, where a fire would endanger workers.  �	On June 8, 2021, the absence of any spark detection and either extinguishing methods or methods of diversion away from the collector in the duct enabled a fire to ignite in the dust collector resulting in the evacuation of the facility, fire department response and intervention, and the destruction of the working components of the dust collector.  �	On June 17, 2021, a second fire ignited in the dust collector due to the absence of any spark detection and either extinguishing methods or methods of diversion away from the collector in the duct, resulting in the evacuation of the facility, fire department response and intervention, and the destruction of the working components of the dust collector.  �	On November 9, 2021, a third fire ignited in the dust collector due to inadequate spark detection and either extinguishing methods or methods of diversion away from the collector in the duct, resulting in the evacuation of the facility, fire department response and intervention, and the destruction of the working components of the dust collector.
Recent events (2)
  • — I (S) $9216
  • — Z (S) $12288

View ROTOBEC USA, INC.'s full OSHA safety record →