Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: LOUTH CALLAN RENEWABLES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LOUTH CALLAN RENEWABLES, LLC in 6 JEFFERSON DRIVE, COVENTRY, RI 02816 (NAICS 221114). OSHA activity number 345417596.

Watch Louth Callan Renewables, LLC — free Get an email when a new federal OSHA severe-injury report for Louth Callan Renewables, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6 JEFFERSON DRIVE
City
COVENTRY
State
RI
ZIP
02816
Mailing
921 THRALL AVENUE, SUFFIELD, CT 06078
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
42
Ownership type
A

3 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $896.00 · Current $448.00 Reduced
29 CFR  1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  (a) Establishment:  As of April 26, 2022, the employer had not certified to OSHA that the abatement had been completed for Citation 1, Item 1 from inspection number 1541759, issued on 9/7/2021, with a final order date of 3/3/2022.
Recent events (3)
  • — F (O) $448
  • — C (O) $896
  • — Z (O) $896

1903.19 D01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1903.19(d)(1):The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:  (a) Establishment:  As of April 26, 2022, the employer had not provided the required abatement documentation to OSHA for Citation 1, Item 1 from inspection number 1541759, issued on 9/7/2021, with a final order date of 3/3/2022.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1926.501 B01

Repeat Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $21026.00 · Current $12616.00 Reduced
29 CFR  1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  (a) At the worksite:  On or about 7/14/2021, employees engaged in solar panel installation on a low sloped roof (approximately 2/12 pitch), were not protected by a guardrail system, a safety net system or a personal fall arrest system, exposing the employees to a fall hazard of approximately 18 feet.  Louth Callan Renewables, LLC was previously cited for a violation of this occupational safety and health standard, 29 CFR  1926.501(b)(1), which was contained in OSHA inspection number 1510228, citation number 001, item number 2a and was affirmed as a final order on 3/30/2021, with respect to a workplace located at 2030 Nooseneck Hill Road, Coventry, RI 02816.
Recent events (3)
  • — F (R) $12615.6
  • — C (R) $21026
  • — Z (R) $21026

View LOUTH CALLAN RENEWABLES, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345417596.