OKLAHOMA CITY, OK —
OSHA Inspection: PREMIERCRAFT INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PREMIERCRAFT INC. in 1316 SOUTHEAST GRAND BOULEVARD, OKLAHOMA CITY, OK 73129 (NAICS 332323). OSHA activity number 345473854.
Where did this inspection happen?
- Establishment
- PREMIERCRAFT INC.
- Site address
- 1316 SOUTHEAST GRAND BOULEVARD
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73129
- Mailing
- 1316 SOUTHEAST GRAND BOULEVARD, OKLAHOMA CITY, OK 73129
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $2341.00 · Current $1405.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. On or about August 12, 2021, and at times prior thereto, at the establishment, the employer did not establish a Lockout/Tag-out program consisting of an energy control procedures, employee training and periodic inspections in maintenance testing operations. This exposed employees to hazards from the unexpected released of energy.
Recent events (2)
- — I (S) $1404.6
- — Z (S) $2341
1910.212 A01
- Issued
- Penalty
- Initial $2341.00 · Current $1405.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. On or about August 12, 2021, and at times prior thereto, the employer did not ensure machines were properly guarded. Employees operating the machines were exposed to the following: a. In the Metal Fabrication and Welding shop, an hydraulic press brakes was not guarded at the point-of-operation. Employees operated the machine with either the foot pedal or the two-hand control and this exposed the employees to caught-in hazards. b. In the Welding shop, the guard for a shear was not properly installed to prevent hands or fingers from contacting the blade while it is in operation. This exposed employees to caught-in hazards. c. In the Welding shop, the guard for a horizontal band saw was not adjusted to cover the unused portion of the blade to prevent hands or fingers from contacting the blade while it is in operation. This exposed employees to caught-in hazards.
Recent events (2)
- — I (S) $1404.6
- — Z (S) $2341
1910.303 B02
- Issued
- Penalty
- Initial $2341.00 · Current $1405.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. On or about August 12, 2021, and at times prior thereto, at the air dry machine, the employer did not ensure that a relocatable-power-tap (RPT) was being used in accordance with the listing instructions. This exposed the employees to a fire hazard.
Recent events (2)
- — I (S) $1404.6
- — Z (S) $2341
1910.304 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served. On or about August 12, 2021, or at times prior thereto, in the break room, the employer did not ensure that a microwave oven and a refrigerator were not plugged into the same outlet. The outlet had a current rating less than the load being served and this exposed the employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at PREMIERCRAFT INC.
OKLAHOMA CITY, OK—2014-12-11 00:00:00
PREMIERCRAFT INC.
View PREMIERCRAFT INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332323)
PACOIMA, CA—2026-07-14 00:00:00
AMERICAN IRONWORKS MANUFACTURING, INC.
PATERSON, NJ—2026-07-08 00:00:00
TOWN GATE CO. INC.
HUDSON, NC—2026-07-01 00:00:00
161479 - TRINITY MANUFACTURING GROUP, LLC
ARCHBOLD, OH—2026-06-30 00:00:00
BIL-JAX INC.
IRVINE, CA—2026-06-29 00:00:00
MISSION VIEJO ORNAMENTAL IRON, INC.
More inspections in OK
TULSA, OK—2026-07-15 00:00:00
LA UNION 7 LLC
STILLWATER, OK—2026-07-13 00:00:00
LATSHAW DRILLING COMPANY
BROKEN ARROW, OK—2026-07-10 00:00:00
AMERICAN WHEATLEY
TINKER AFB, OK—2026-07-09 00:00:00
U.S. DEPARTMENT OF DEFENSE, TINKER AIR FORCE BASE
OCHELATA, OK—2026-07-08 00:00:00
WALMART, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345473854.