EAST ALTON, IL —
OSHA Inspection: OLIN WINCHESTER, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OLIN WINCHESTER, LLC in 600 POWDER MILL ROAD, EAST ALTON, IL 62024 (NAICS 332994). OSHA activity number 345483960.
Where did this inspection happen?
- Establishment
- OLIN WINCHESTER, LLC
- Site address
- 600 POWDER MILL ROAD
- City
- EAST ALTON
- State
- IL
- ZIP
- 62024
- Mailing
- 600 POWDER MILL ROAD, EAST ALTON, IL 62024
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332994
- Employees
- 714
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.217 C02 I A
- Issued
- Abate by
- Penalty
- Initial $13653.00 · Current $11605.00 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a):Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): On and prior to August 10, 2021, the point of operation barrier guard, on the Ejection Cartridge Capper, full revolution mechanical power press, located in building T-285, did not prevent the entry of hands or fingers into the point of operation by reaching under the interlocked hinged section of the guard.
Recent events (3)
- — F (S) $11605.05
- — C (S) $13653
- — Z (S) $13653
1910.217 C02 V
- Issued
- Penalty
- Initial $11264.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(v):The hinged or movable section(s) of interlocked press barrier guard(s) on mechanical power press(es) did not prevent opening of the interlocked section and reaching into the point of operation prior to die closure or prior to the cessation of slide motion: On and prior to August 10, 2021, the hinged section of the point of operation barrier guard, on the Ejection Cartridge Capper, full revolution mechanical power press, located in building T-285, was not properly interlocked. The installed interlock device did not prevent opening of the interlocked hinged guard prior to the cessation of the slide motion.
Recent events (3)
- — F (S) $0
- — C (S) $11264
- — Z (S) $11264
1910.217 D01 II
- Issued
- Penalty
- Initial $11264.00 · Current $9574.00 Reduced
General-duty citation text
29 CFR 1910.217(d)(1)(ii):Hand tool(s) were not used for freeing and removing stuck work or scrap pieces from the die(s) of mechanical power press(es) so that no employee needed to reach into the point of operation for such purposes: On and prior to August 10, 2021, the employer did not provide, and require the use of, hand tools to remove misfed shells from the dies on the Ejection Cartridge Capper, full revolution mechanical power press, located in building T-285.
Recent events (3)
- — F (S) $9574.4
- — C (S) $11264
- — Z (S) $11264
More inspections at OLIN WINCHESTER, LLC
EAST ALTON, IL—2026-02-06 00:00:00
OLIN WINCHESTER, LLC
OXFORD, MS—2025-06-23 00:00:00
OLIN WINCHESTER, LLC
INDEPENDENCE, MO—2025-04-21 00:00:00
OLIN WINCHESTER LLC
EAST ALTON, IL—2024-10-25 00:00:00
OLIN WINCHESTER, LLC
EAST ALTON, IL—2023-06-23 00:00:00
OLIN WINCHESTER, LLC
View OLIN WINCHESTER, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332994)
MARYVILLE, TN—2026-07-07 00:00:00
SMITH & WESSON BRANDS, INC.
RAPID CITY, SD—2026-06-17 00:00:00
JACK FIRST, INC.
LOUISVILLE, CO—2026-05-21 00:00:00
MAGPUL INDUSTRIES CORP.
WATERTOWN, WI—2026-03-19 00:00:00
HEARING PROTECTION, LLC
WEST VALLEY CITY, UT—2026-03-11 00:00:00
DESERT TECH
More inspections in IL
FRANKFORT, IL—2026-07-17 00:00:00
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17 00:00:00
AUGUSTANA COLLEGE
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
FOREST PARK, IL—2026-07-17 00:00:00
CONSERVATION OF SCULPTURE & OBJECTS STUDIO, INC.
BLUE ISLAND, IL—2026-07-17 00:00:00
PROFLOW PUMPING SOLUTIONS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345483960.