TAMUNING, GU —
OSHA Inspection: GUAM REEF HOTEL
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GUAM REEF HOTEL in 1317 PALE SAN VITORES ROAD, TAMUNING, GU 96931 (NAICS 721110). OSHA activity number 345509533.
Where did this inspection happen?
- Establishment
- GUAM REEF HOTEL
- Site address
- 1317 PALE SAN VITORES ROAD
- City
- TAMUNING
- State
- GU
- ZIP
- 96931
- Mailing
- 1317 PALE SAN VITORES ROAD, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721110
- Employees
- 60
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $3481.00 · Current $2437.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program that would describe or include at least the following: Maintenance and Engineering: The written Hazard Communication Program did not include a description of the pictogram system, and the definition of the Global Harmonization system (GHS). Employees were exposed to chemical hazards.
Recent events (2)
- — I (S) $2436.7
- — Z (S) $3481
1910.1200 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1)(i): At this establishment, the employer's written Hazard Communication Program did not include a complete chemical inventory list of the hazardous chemicals known to be present in the workplace. Maintenance and Engineering Department: The written hazard Communication Program did not include a list of hazardous chemicals used in the workplace. Maintenance and engineering employees used flammable product such as paints, thinners, and welding gases as well as caustic products to maintain HVAC systems. Employees were exposed to chemical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they are readily accessible during each work shift to employees when they are in their work area(s). Engineering/Maintenance Department - The employer did not obtain safety data sheets (SDS's) for hazardous chemicals used in the department. Employees used flammable products such as but not limited to, acetylene, paints, and thinners as well as corrosive products. Employees were exposed to chemical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition: Boiler Room and Shop - Walking-working surfaces were not maintained; various types of materials such as paint buckets, tools, cardboard and trash was strewn throughout. Employees are exposed to trip and fall hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.25 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.25(b)(1): The employer did not ensure handrails, stair rail systems, and guardrail systems were provided in accordance with 1910.28: a. Cooling tower - The stairs leading to the cooling tower were not equipped with mid-railings on both the left and right sides. Employees were exposed to slip, trip, and fall hazards. b. Shop - The stairs leading to the upstairs storage area were not equipped with top and mid-railings on both the left and right sides. Employees were exposed to slip, trip, and fall hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment Boiler Room and Shop - Various types of materials and trash were blocking two live electrical panel boards (120 V, 3-phase) preventing 3-ft. clearance. Employees are exposed to trip and fall hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GUAM REEF HOTEL
TAMUNING, GU—2017-11-01 00:00:00
GUAM REEF HOTEL
TAMUNING, GU—2013-02-07 00:00:00
GUAM REEF HOTEL
TUMON, GU—1984-08-08
GUAM REEF HOTEL
View GUAM REEF HOTEL's full OSHA safety record →
More inspections in this industry (NAICS 721110)
LAS VEGAS, NV—2026-07-13
THE BERKLEY LAS VEGAS
LYNCHBURG, VA—2026-07-10
RIVERFRONT HOSPITALITY LLC
INCLINE VILLAGE, NV—2026-07-09
SHANTI RAHM LLC.
INCLINE VILLAGE, NV—2026-07-09
SHANTI RAHM LLC.
ISELIN, NJ—2026-07-09
DELTA HOTELS WOODBRIDGE
More inspections in GU
BARRIGADA, GU—2026-01-22
DURI CORPORATION
TAMUNING, GU—2026-01-21
DLR CORPORATION
BARRIGADA, GU—2026-01-21
DURI CORPORATION
TAMUNING, GU—2026-01-20
MG CONSTRUCTION COMPANY
BARRIGADA, GU—2026-01-20
PFM -VERTEX-LMS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345509533.