LOUVIERS, CO —
OSHA Inspection: FOM, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FOM, LLC in 8230 N. CORA ST., LOUVIERS, CO 80131 (NAICS 332710). OSHA activity number 345637847.
Where did this inspection happen?
- Establishment
- FOM, LLC
- Site address
- 8230 N. CORA ST.
- City
- LOUVIERS
- State
- CO
- ZIP
- 80131
- Mailing
- PO BOX 129, LOUVIERS, CO 80131
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 13
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $2486.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) On or about November 10, 2021, and at times prior, the employer did not ensure that pulley on the belt and pulley apparatus in the cabinet of the vertical bandsaw was guarded. The pulley is located approximately one foot from the operator's feet. This condition exposed employees to hazards of contacting rotating pulleys and belts.
Recent events (2)
- — I (S) $1500
- — Z (S) $2486
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about November 10, 2021, and at times prior, the employer did not ensure that the band saw blade in the cabinet of the vertical bandsaw was guarded. The blade is located approximately one foot from the operator's feet. This condition exposed employees to hazards of contacting rotating ingoing nip points and the exposed blade.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Penalty
- Initial $2486.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about November 10, 2021, and at times prior, the employer did not ensure that air wand tool supplied with air pressure at the machines used for cleaning was reduced to less than 30 p.s.i.
Recent events (2)
- — I (S) $0
- — Z (S) $2486
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
2310
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On or about November 10, 2021, and at times prior, the employer did not furnish flushing facilities in the immediate area of corrosive materials for emergency use. The eyewash was located in the bathroom, past a potentially locked door and more than a 10 second walk from the battery operated forklift charging station. Abatement Note: American National Standards Institute (ANSI) Z358.1-1998, Emergency Eyewash and Shower Equipment, which states, at section 7.4.4, that eyewash facilities are to be located to require no more than 10 seconds to reach but that where a strong acid or caustic is used, the unit should be immediately adjacent to the hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.212 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) On or about November 10, 2021, and at times prior, the employer did not provide anchoring for the drill press machine to prevent walking or moving while in operation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about November 10, 2021, and at times prior, flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. A fan, phone charger, and another extension cord for machinery computers were being used to supply power by the Mori Seki CNC machine work table.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at FOM, LLC
LOUVIERS, CO—2018-10-31 00:00:00
FOM, LLC
View FOM, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332710)
CAMBRIDGE, MN—2026-07-09
111567 - VISION MACHINE INC
SAINT PAUL, MN—2026-07-09
111558 - ST PAUL MACHINE - DESIGN INC
EVERETT, WA—2026-07-07
WA317991968 - ONOMAC INDUSTRIES INC
SOUTH DEERFIELD, MA—2026-07-07
VISION MACHINING INC
LAKEVILLE, MN—2026-07-02
111518 - KD HOLDING COMPANY INC DBA MEDFAB MANUFACTURING CO
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source