BLOOMFIELD, CT —
OSHA Inspection: COHERENT, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of COHERENT, INC. in 1280 BLUE HILLS AVENUE, BLOOMFIELD, CT 06002 (NAICS 333517). OSHA activity number 345728489.
Where did this inspection happen?
- Establishment
- COHERENT, INC.
- Site address
- 1280 BLUE HILLS AVENUE
- City
- BLOOMFIELD
- State
- CT
- ZIP
- 06002
- Mailing
- 1280 BLUE HILLS AVENUE, STE. A, BLOOMFIELD, CT 06002
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333517
- Employees
- 227
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.304 B04 II B
- Issued
- Penalty
- Initial $5283.00 · Current $5283.00
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4: Storage Area: On, or about, January 13, 2022, a 15 ampere relocatable power tap was used to energize a DeWalt Model DW716 chop saw, a Metcal Model MX1 69470 soldering gun, a light and a label maker. The combined load of the devices exceeded the maximum load allowed on the relocatable power tap, which was 12 amperes.
Recent events (1)
- — Z (S) $5283
1910.303 G01
- Issued
- Penalty
- Initial $31075.00 · Current $31075.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Chilled Water Treatment Area: On, or about, January 13, 2022, access to an Eaton and two Square D electrical panels was limited due to items in storage. Coherent, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection Number 1236146, Citation Number 1, Item Number 5b and was affirmed as a Final Order on August 5, 2017, with respect to a workplace located at Bloomfield, Connecticut.
Recent events (1)
- — Z (R) $31075
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Company: On, or about, December 14, 2021, the employer had not conducted a documented, periodic review of the lockout/tagout procedures for machinery and equipment in the facility.
Recent events (1)
- — Z (O) $0
More inspections at COHERENT, INC.
MONROE, CT—2025-01-21
COHERENT, INC.
NEWTOWN, CT—2023-10-24 00:00:00
COHERENT, INC
BLOOMFIELD, CT—2021-12-14 00:00:00
COHERENT, INC.
BLOOMFIELD, CT—2017-05-31 00:00:00
COHERENT, INC.
EAST HANOVER, NJ—2017-03-16 00:00:00
COHERENT INC.
View COHERENT, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333517)
THREE RIVERS, MI—2026-06-16
W F WELLS INC
EVANSVILLE, IN—2026-06-09
HOOSIER STAMPING
RENO, NV—2026-06-04
THE LINCOLN ELECTRIC COMPANY
SPARKS, NV—2026-05-13
SAMCO FABRICATION LLC
CHICAGO, IL—2026-04-28
INDUSTRIAL MAINTENANCE, WELDING AND MACHINING COMPANY, INC.
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source