Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: COHERENT, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COHERENT, INC in 31 PECKS LANE, NEWTOWN, CT 06470 (NAICS 333242). OSHA activity number 347055725.

Watch Coherent, INC — free Get an email when a new federal OSHA severe-injury report for Coherent, INC is published. One employer, no account, unsubscribe in one click.
Establishment
COHERENT, INC
Site address
31 PECKS LANE
City
NEWTOWN
State
CT
ZIP
06470
Mailing
31 PECKS LANE SUITE 8, NEWTOWN, CT 06470
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333242
Employees
60
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Other-than-serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $8929.00 · Current $6250.00 Reduced
29 CFR1910.212(a)(1):  One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  a) Workshop:  On or about October 24, 2023 the employer did not ensure the Lapmaster 56R table roller guards were properly adjusted exposing employees to caught-in and crushing hazards.  b) Workshop:  On or about October 24, 2023 the employer did not ensure the Lapmaster 48 table roller guards were properly adjusted exposing employees to caught-in and crushing hazards.
Recent events (2)
  • — I (O) $6250.3
  • — Z (S) $8929

1910.242 B

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $6696.00 · Current $4687.00 Reduced
29 CFR1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 (psi) pounds per square inch.  Workshop:  On or about October 24, 2023 a blue shop air blow gun being used at a workbench across from lapping machine 48 for blowing off metal particles and nuisance particulate was digitally measured with a tip discharge peak pressure of 106.9 psi.
Recent events (2)
  • — I (O) $4687.2
  • — Z (S) $6696

1910.147 C06 I

Repeat 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $446.00 · Current $312.00 Reduced
29 CFR1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  Company:  On or about October 24, 2023 the employer had not conducted a documented periodic review of the lockout/tagout procedures for machinery and equipment in the facility.  Coherent was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 1572848, citation number 3, item number 1 and was affirmed as a final order on April 7, 2022, with respect to a workplace located at 1280 Blue Hills Avenue Bloomfield, CT 06002.
Recent events (2)
  • — I (R) $312.2
  • — Z (R) $446

View COHERENT, INC's full OSHA safety record →

ASML