Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ALVARADO STONE LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALVARADO STONE LLC in 5503 JFK, NORTH LITTLE ROCK, AR 72113 (NAICS 238140). OSHA activity number 345775951.

Watch Alvarado Stone LLC — free Get an email when a new federal OSHA severe-injury report for Alvarado Stone LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ALVARADO STONE LLC
Site address
5503 JFK
City
NORTH LITTLE ROCK
State
AR
ZIP
72113
Mailing
1922 S. MARTIN STREET, LITTLE ROCK, AR 72204
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 5 6 instances 6 exposed
Issued
Abate by
Penalty
Initial $3108.00 · Current $3108.00
29 CFR  1926.100(a):Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:  On or about 2/10/2022 at the jobsite, employees were not wearing hard hats while installing cultured stone overhead from a multi-level scaffold.
Recent events (1)
  • — Z (S) $3108

1926.404 A02

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $3108.00 · Current $3108.00
29 CFR  1926.404(a)(2):A grounded conductor was attached to a terminal or lead so as to reverse designated polarity:  At the jobsite, employees using tools and equipment receiving power from extension cords were exposed to electrical shock hazards in the following instances:  a) Extension cord #1 (orange with a black male connector) plugged in upside down;  b) Extension cord #2 (orange with a orange male connector) plugged in upside down.
Recent events (1)
  • — Z (S) $3108

1926.404 F06

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:   At the jobsite, employees using tools and equipment receiving power from extension cords were exposed to electric shock in that the ground pins were missing in the following instances:  a) Extension cord #1 (orange with a black male connector)   b) Extension cord #2 (orange with a orange male connector)
Recent events (1)
  • — Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $4351.00
29 CFR  1926.451(e)(1):  When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Cross braces were used as a means of access:  On or about 2/10/2022, at the jobsite on the south and east corners of the structure, employees were observed climbing the frames of the scaffold to access and egress from the second and third platform levels, measured to be approximately 14 and 20 feet, respectively, above the ground a practice that exposed them to the hazard of falling from the scaffold to the ground.
Recent events (1)
  • — Z (S) $4351

1926.451 E06 I

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(e)(6)(i): Integral prefabricated scaffold access frames were not specifically designed or constructed for use as ladder rungs:   On or about 2/10/2022, at the jobsite on the south and east corners of the structure, employees were observed climbing the frames of the scaffold to access and egress from the second and third platform levels, measured to be approximately 14 and 20 feet, respectively, above the ground, a practice that exposed them to the hazard of falling from the scaffold to the ground.
Recent events (1)
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 17 instances 6 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $4351.00
29 CFR  1926.451(g)(1):  Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level.  On or about 2/10/2022, at the jobsite on the south and east corners of the structure,  employees working from the scaffold system were exposed to the hazard of falling from the scaffolds in the following instances:  a-g) third level, 7 unguarded platforms;  h-j) second level, east side, 3 platforms--no midrails;  k-l) second level, east side, 2 end frames--no guarding;  m-o) second level, south side, 3 platforms--no midrails;  p) second level, west end of south side--no guarding;  q) second level, south side, west end crossover platform--no guarding.
Recent events (1)
  • — Z (S) $4351

View ALVARADO STONE LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345775951.